Seiko 5J32A III. Value Checking and Adjustment, Coil block resistance, How to check the leakage

Page 15

TECHNICAL GUIDE

Cal. 5J32A

III.VALUE CHECKING AND ADJUSTMENT

Coil block resistance

Second coil block : 2.00 K

~ 2.45 K

Hour and minute coil block :

 

 

Coil for driving hands

:

1.00 K~ 1.20 K

Coil for detecting generation :

280 ~ 360

Note: Measure the coil block resistance after installing each coil block to the movement, checking that stable measurements may be obtained.

*The motor driving the hour and minute hands uses a special driving system so that they move quickly to indicate the current time immediately after the time relay function is activated. The hour and minute coil block has two layers of coils, one for driving hands and the other for detecting generation, and it is necessary to measure the resistance of each layer of coil.

The illustration below shows the patterns to which the probes of the tester should be applied to measure the resistance of the respective coils.

Patterns for checking

A

a

 

the coil for driving hands

 

B

b

 

Patterns for checking

the coil for detecting generation

Checking for leakage between coil for driving hands and coil for detecting generation

*If the hour and minute hands do not move properly when the time relay function is activated, that is, if they remain stopped or will not move smoothly, check for the leakage between coil for driving hands and coil for detecting generation. This checking is required only if such a problem is found.

If leakage is detected, replace the hour and minute coil block with a new one.

How to check the leakage

1.Make the tester ready for measuring the resistance.

2.Apply the probes of the tester to 1 “A” and “a”, 2 “A” and “b”, 3 “B” and “a”, and 4 “B” and “b”, respectively, to measure the resistance.

3.If the four measurements obtained are all infinitely great, that is, if the resistance was unable to be

measured for all the four cases, there is no leakage between coil for driving hands and coil for detecting generation. As a guideline, there is a leakage if measurements of less than 2 Kwere obtained.

Generating coil block resistance

340 ~ 440

Note: Measure the generating coil block resistance after installing it to the movement, checking that stable measurements are obtained.

15

Image 15
Contents Cal. No 5J32A SpecificationsTime Relay Function Power Save FunctionAutomatic power save function Manual power save functionRemarks on removing the winding stem Lubricating Types of oil Oil quantityParts Catalogue Parts Catalogue Parts Catalogue Structure of the Circuit Block Identification of circuit blockHow to install Setting positionII. Remarks on Disassembling and Reassembling Please insert the pivot of the day-date corrector wheel here How to remove LubricatingLubricating Moebius a Technical Guide Moebius a Moebius F See the illustration at right Activated Generating coil block resistance III. Value Checking and AdjustmentHow to check the leakage Coil block resistanceCurrent consumption Checking the automatic generating system For your information Number of swings and power reserve Checking the manual power save and time relay functionsInitial voltage and guidelines of normal/defective decision IV. Troubleshooting Guide Checking procedureImportant functions characteristic of Cal J32A Technical Guide Problems, causes and methods of repairTechnical GUIDE, General Instructions CAL Identification of 5J series circuit blocks 2002-4