Finisar Brocade Fabric Watch manual Threshold name is envFan000 envFan002 Example

Page 26

A

Example Error Message

Note: Threshold name = class name + area name + element index.

Example: FopportLink003, fabricFL000, alpaPerfCRC004

Example 1:

class name = env,

area name = Fan,

element index = 000-002

threshold name is envFan000 – envFan002

Example 2:

class name = gbic,

area name = Temp

element index = 001-00x

threshold name is gbicTemp001-gbicTemp00x

Table A-1Fabric Watch Threshold Class / Area Abbreviation Table

Class name: class abbreviation

Area name: area abbreviation

 

 

Environment: env

Power supply: PS

 

 

 

Temperature (sensor): Temp

 

 

 

Fan speed sensor: Fan

 

 

Gigabit Interface Converter: gbic

Temperature (sensor): Temp

 

 

 

Receiver power: RXP

 

 

 

Transmitter power: TXP

 

 

 

Current: Crnt

 

 

A-2

Fabric Watch User’s Guide

Image 26
Contents Brocade Fabric WatchTM Copyright Contents Appendix a Example Error Message Related Publications PrefaceAbout This Guide ChapterClick MIBs and RSH Utilities Getting Software UpdatesGetting Help Introducing Brocade Fabric Watch OverviewThreshold Behavior Models Range Threshold1Example of Range Threshold Temperature Celsius Rising/Falling Threshold2Example of Rising/Falling Threshold Error Rate Change Monitor ThresholdInstalling Fabric Watch Installing through TelnetInstalling through Brocade Web Tools User Interfaces Using Fabric WatchOverview Brocade Web ToolsTelnet Interface Configuration FileProfiles SNMP-Based Enterprise ManagersClasses Class Area Description End-to-EndFilter FLPort OpticalCopper Threshold Naming Conventions Class AbbreviationEvents Triggered EventsSnmp Trap AlarmsError Log Entry Locking the Port LogThreshold Values Configuring Thresholds and AlarmsEmail Alert Threshold Area Values Using Fabric Watch Example Error Message Figure A-1 shows a typical Fabric Watch Errlog messageExample Threshold name is envFan000 envFan002 ExampleFabric fabric Example Error Message Ansi API GlossaryAlpa Asic ATM AwtovBrocade AccessTMBroadcast DistributedCRC DLSFC-AL-3 FC-FLA FCP FC-PH-1, 2, 3 FC-PI FC-PLDA FSP FlogiFRU GbicLIP Lmtov IOD ISLJbod Lpsm LWL MIBRatov RAID PlogiPost RrtovSWL SnmpSNS UDP ULP Ulptov WWNIndex Snmp

Brocade Fabric Watch specifications

Finisar Brocade Fabric Watch is an advanced network management solution designed to simplify the monitoring and administration of storage networks. Its primary goal is to enhance the performance and reliability of data center operations by providing comprehensive visualization and management capabilities.

One of the standout features of Fabric Watch is its ability to deliver real-time monitoring of the health and performance of network devices. This is critical for organizations that require constant uptime and high availability for their storage systems. Fabric Watch continuously assesses the status of switches, routers, and other devices within the fabric, enabling administrators to quickly identify potential issues before they escalate into problems that could disrupt operations.

The technology behind Fabric Watch encompasses various innovative aspects that enhance its functionality. For instance, the solution uses advanced analytics to assess historical performance trends, allowing IT teams to predict potential bottlenecks and optimize resource allocation effectively. This predictive capability not only improves operational efficiency but also reduces the risk of downtime, ensuring that organizations can maintain consistent access to critical data.

Furthermore, Fabric Watch supports a range of protocols and standards, making it compatible with various environments and configurations. This flexibility is crucial for companies that have heterogeneous systems and diverse technology stacks. As a result, organizations can deploy Fabric Watch across different platforms, ensuring a unified approach to network management.

Another notable characteristic of Fabric Watch is its intuitive user interface, which makes it user-friendly for administrators of varying skill levels. The dashboard presents a centralized view of the entire storage network, complete with graphical representations of performance metrics, alerts, and health statuses. This visual approach facilitates rapid decision-making, allowing teams to address issues quickly and maintain optimal performance.

In addition, Fabric Watch integrates seamlessly with existing data center management tools and workflows, providing a holistic view of the infrastructure. This integration capability supports broader initiatives around automation and orchestration, enabling organizations to create more streamlined and efficient operational processes.

In summary, Finisar Brocade Fabric Watch stands out as a robust solution for managing and monitoring storage networks. Its real-time monitoring, predictive analytics, compatibility across platforms, and user-friendly interface make it an essential tool for IT teams seeking to enhance performance and reliability in today’s demanding data environments. By employing Fabric Watch, organizations can better navigate the complexities of their storage networks, ensuring they remain agile and responsive to business needs.