Membrane Pad Checks
On the MDE/DG5500 dryer you can perform the Membrane Pad Check with the control console. (See Section 9: Accessing Service Mode; Membrane Pad Check)
On both dryers, you can check the mem- brane pads, by pulling the J7 connector from the machine control board and locating the corresponding switch pin numbers in the ribbon harness.
LCD Dryer
| Membrane Pad |
| Pin Number |
| Pin Number |
|
|
|
|
|
|
|
|
| home |
| J7(3) |
| J7(5) |
|
|
|
|
|
|
|
|
| favorites |
| J7(4) |
| J7(5) |
|
|
|
|
|
|
|
|
| back |
| J7(3) |
| J7(6) |
|
|
|
|
|
|
|
|
| start/pause |
| J7(3) |
| J7(7) |
|
|
|
|
|
|
|
|
| off |
| J7(4) |
| J7(7) |
|
|
|
|
|
|
|
|
| help |
| J7(4) |
| J7(6) |
|
|
|
|
|
|
|
|
| LED Dryer |
|
|
|
|
|
|
|
|
|
|
|
|
| Membrane |
| Pin Number |
| Pin Number |
|
| Pad |
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| sensor dry |
| J7(12) |
| J7(13) |
|
|
|
|
|
|
|
|
| time dry |
| J7(11) |
| J7(13) |
|
|
|
|
|
|
|
|
| time (+ ) |
| J7(10) |
| J7(13) |
|
|
|
|
|
|
|
|
| time |
| J7(9) |
| J7(13) |
|
|
|
|
|
|
|
|
| Dry Temp (^ ) |
| J7(11) |
| J7(14) |
|
|
|
|
|
|
|
|
| Dry Temp (v) |
| J7(10) |
| J7(14) |
|
|
|
|
|
|
|
|
| Dryness(< ) |
| J712) |
| J7(14) |
|
|
|
|
|
|
|
|
| Dryness(> ) |
| J7(9) |
| J7(14) |
|
|
|
|
|
|
|
|
| wrinkle release |
| J7(11) |
| J7(15) |
|
|
|
|
|
|
|
|
| press care |
| J7(9) |
| J7(15) |
|
|
|
|
|
|
|
|
| air fluff |
| J710) |
| J7(15) |
|
|
|
|
|
|
|
|
| start/pause |
| J7(11) |
| J716) |
|
|
|
|
|
|
|
|
| signal |
| J7(12) |
| J7(15) |
|
|
|
|
|
|
|
|
| off |
| J7(9) |
| J7(16) |
|
|
|
|
|
|
|
|
| signal (+ ) |
| J7(12) |
| J7(16) |
|
|
|
|
|
|
|
|
16023110 | Section 2. Electrical Components & Testing | |
16010279 |
|
|
© 2000 Maytag Appliances Sales Company | |
|