Whirlpool CEDC392PQ0 Install Vent System, Install Cord Bracket and Casters, Determine vent length

Page 8

Determine vent length

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns when possible.

better good

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

B

A

4"

(10.2 cm)

4" (10.2 cm)

A. Louvered style

B. Box hood style

The angled hood style (shown following) is acceptable.

4"

(10.2 cm)

2½" (6.4 cm)

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

3.Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.

Vent Length Chart

Number of

Type of

Box or

Angled

90º turns

vent

louvered

hoods

or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

36 ft (11 m)

26 ft (7.9 m)

 

Flexible metal

28 ft (8.5 m)

22 ft (6.7 m)

 

 

 

 

1

Rigid metal

26 ft (7.9 m)

16 ft (4.9 m)

 

Flexible metal

18 ft (5.5 m)

12 ft (3.7 m)

 

 

 

 

2

Rigid metal

16 ft (4.9 m)

6 ft (1.8 m)

 

Flexible metal

8 ft (2.8 m)

2 ft (0.6 m)

Install Vent System

1.Before installing the vent system, be sure to remove the wire exhaust guard that is located at the exhaust outlet.

2.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

3.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

4.Run vent to dryer location. Use the straightest path possible. See “Determine vent length.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

Install Cord Bracket and Casters

Do not move dryer into its final position until the following steps have been performed.

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer. Failure to do so can result in back or other injury.

Install cord bracket

1.Remove tape from the power cord and the rear panel.

8

Image 8
Contents Volt Compact Electric Dryer 8562112Table of Contents Dryer Safety Your safety and the safety of others are very importantLocation Requirements Installation InstructionsTools and Parts Dryer Dimensions Recessed or closet installation Dryer onlyRecessed or closet installation Stacked Mobile home installations requireElectrical Requirements Venting RequirementsPlan Vent System Alternate installations for close clearancesSpecial provisions for mobile home installations Install Vent System Install Cord Bracket and CastersInstall cord bracket Determine vent lengthComplete Installation Install castersConnect Vent If the dryer will not start, check the followingDryer USE Starting Your DryerStopping and Restarting To stop your dryerCycles Drying, Cycle, and Temperature TipsLoading Dryer Care Troubleshooting Assistance or Service If you need replacement partsFor assistance or service Accessories U.S.APage 8562112 Crosley Dryer WarrantyWhirlpool Corporation will not pay for