INSTALLATION REQUIREMENTS
Tools and Parts
Tools needed
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Stack Kit
Are you planning to stack your washer and dryer? To do so, you will need to purchase a Stack Kit.
To order, call the dealer from whom you purchased your dryer or refer to the “Assistance or Service” section of this manual. Ask for Part Number 8182452.
■
■Adjustable wrench
■T20 TORX®† screwdriver
■Wire stripper (direct wire installations)
■7 mm nut driver
■Caulking gun and compound (for installing new exhaust vent)
■Tin snips (new vent installations)
■Wood block
■Level
■Vent clamps
Location Requirements
WARNING
Parts supplied
Remove parts package from the dryer drum. Check that all parts listed are included.
Coupling
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor for a garage installation.
Failure to do so can result in death, explosion, or fire.
Parts needed
Check local codes, existing electrical supply and venting, and see “Venting Requirements” and “Electrical Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware. For ordering information, please refer to the “Assistance or Service” section of this manual. You may also contact the dealer from whom you purchased your dryer.
Options
Pedestal
You may order a pedestal separately for this dryer. This pedestal will add about 12" (30.48 cm) to the height of your unit for a total height of approximately 45" (114.3 cm).
Optional pedestal
To order, call the dealer from whom you purchased your dryer or refer to the “Assistance or Service” section of this manual. Ask for Model Number LAB0050PQ.
You will need
■A location that allows for proper exhaust installation. See “Venting Requirements.”
■A separate
■If you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”
■A sturdy floor to support the dryer weight (dryer and load) of 115 lbs (52 kg). The combined weight of a companion appliance should also be considered.
■A level floor with a maximum slope of 1" (2.5 cm) under entire dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
†®TORX is a registered trademark of Textron Innovations Inc.
4