Whirlpool 8578567 Installation Instructions, Electrical Connection, Power Supply Cord Direct Wire

Page 8

INSTALLATION INSTRUCTIONS

Electrical Connection

Power Supply Cord

 

Direct Wire

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.

Disconnect power.

3.

Unscrew the strain relief from the terminal block cover.

2.

Remove the terminal block cover.

4.

Unscrew the strain relief nut from the strain relief.

 

A

5.

Put the power supply cord through the strain relief nut, then

 

 

 

 

the strain relief. Be sure that the wire insulation on the power

 

 

 

 

 

 

 

 

supply cord is inside the strain relief.

 

 

 

C

 

 

 

 

 

 

A

B

B

C

A. UL listed strain relief

B. Strain relief nut

C. Power cord

D

A. Terminal block cover

B. Strain relief

C. Center, terminal block screw

D. External ground conductor screw

8

Image 8
Contents Electric Dryer 8578567Table of Contents Dryer Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsLocation Requirements OptionsDryer Dimensions Custom undercounter installation Dryer onlyMobile home installations require Mobile Home Additional Location RequirementsElectrical Connection Electrical RequirementsIt is your responsibility If this is a new vent system Vent material If using an existing vent systemVenting Requirements Electrical Connection Installation InstructionsPower Supply Cord Direct Wire Wire connection Power supply cord Wire connection Direct WireCE F Plan Vent System Alternate installations for close clearancesSpecial provisions for mobile home installations Install Vent System Vent system chartConnect Vent Determine vent pathIf the dryer will not start, check the following Complete InstallationLevel Dryer Changing Cycles and Temperatures Dryer USEStarting Your Dryer Stopping and RestartingCycles Drying, Cycle and Temperature TipsControls Dryer Care Cleaning the Dryer LocationCleaning the Lint Screen Cleaning the Control Panel Cleaning the Dryer InteriorRemoving Accumulated Lint Vacation and Moving CareTroubleshooting Dryer OperationDryer will not run No heatAssistance or Service U.S.AWhirlpool Corporation Major Appliance Warranty 8578567