Whirlpool 8577194 manual ElectricalRequirements, It is your responsibility, Electrical Connection

Page 7

ElectricalRequirements

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.

A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated

120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type

14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

10-gauge solid copper wire (do not use aluminum).

At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

7

Image 7
Contents 8577194 Electronic Electric DryerTable of Contents Your safety and the safety of others are very important Dryer Safety ToolsandParts Installation Instructions Options You will need Dryer DimensionsInstallation clearances Location RequirementsCloset installation, with stacked washer and dryer Minimum installation spacing for cabinet installationMobile home Additional installation requirements Mobile home installations requireIt is your responsibility ElectricalRequirementsElectrical Connection Style 1 Power supply cord strain relief Power Supply Cord Direct WireElectrical Connection Style 2 Direct wire strain relief Wire connection Power supply cordRemove center silver-colored terminal block screw Wire connection Direct wireBDE CG F Optional 3-wire connection VentingRequirements If using an existing vent systemIf this is a new vent system Vent material Alternate installations for close clearances Optional exhaust installationsPlan VentSystem Vent system chart Install VentSystemInstall LevelingLegs Special provisions for mobile home installationsIf the dryer will not start, check the following CompleteInstallationConnectVent LevelDryerStartingYourDryer Dryer USETo use an Automatic Cycle DryingandCycleTips PausingorRestartingStoppingYourDryer ControlLockedStatusLights Cycles Signals Additional FeaturesTemperature When using Air OnlyStuffed toys or pillows Rack Dry Setting Temp Time Wool SweatersDryingRack To use the drying rackDryer Care CleaningtheDryer LocationCleaningtheLintScreen CleaningtheDryerInteriorVacationandMovingCare RemovingAccumulatedLintChangingtheDrumLight DryerOperation TroubleshootingLoads are wrinkled Cycle time too shortLint on load Stains on load or drumAccessories U.S.A Assistance or ServiceIf you need replacement parts For assistance and serviceWhirlpool Corporation will not pay for Whirlpool Dryer Warranty8577194