Tools needed for installation:

adjustable

wrench

dew

glasses

utility

knife

 

level

 

Phillips

screwdriver

pliers

 

Bat-blade

 

duct

tape

screwdriver

 

gloves

 

Parts supplied

for

installation:

 

 

2

slide protectors

8 screws

 

2

slide extensions

2, SO-minute

cams

2

bolt and washer

2,60-minute

cams

 

assemblies

4.314”

wood

screws

Parts owner

must

supply:

1 control panel lock and key

2 coin vaults and keys (E.S.D. vault must have projecting lock.)

2 coin-slide mechanisms (vertical 8)

Parts may be ordered from Greenwald Industries, Inc. or Equipment Systems and Devices, Inc.

l Greenwald Industries, Inc.

1340 Metropolitan Avenue Brooklyn, NY 11237 telephone (7 18) 82 l-9000 or toll free (800) 221-0982 fax(718)417-7412

l Equipment Systems and Devices, Inc.

270 New Jersey Dr.

Fort Washington, PA 19034 telephone (215) 628-0860 or toll free (800) 523- 1510

fax (215) 643-4623

lMonarch P.O. Box 427

105-l 15 East Fourth St. Covington, KY 41011

Gas supply reauhements

Fire Hazard

Dryers must be connected to a regulated gas supply.

Failure to do so could result In hlgh- pressure gas release, resulting In a fire or exploslon.

Have L.P.gas checked by a quallfled person bdore lnstalllng the dryer. The L.P.gas supply must not exceed 13 Inches water column pressure.

New, flexible tublng should be used. Reuslng old, flexible tublng mlght result In possible gas leaks.

Failure to follow these lnstructlons could result In flre or exploslon.

OBSERVEALL GOVERNING CODES AND ORDINANCES.

A n This installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1- latest edition,* and all local codes and ordinances.

B n The desian of this drver has been certified by the American Gas Association for use at altitudes up to 3000 m (10.000 feet) above sea level at the B.T.U. rating indicated on the model/serial rating plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

When installed above 3000 m (10,000 feet), a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial rating plate is required

for each 300 m (1 ,ooO foot) increase in elevation, For assistance when converting to other gas types and/or installing above 3000 m (10,000 feet) elevation, contact your local service company.

C n Check that dryers are equipped with the correct burner for the particular type of gas used. Burner information will be found on the rating plate in door well of the appliance. If thls information does not agree with the type of gas available, see your dealer.

D n These dryers are shipped for use with NATURAL GAS.

They are certified by the American Gas Association for

manufactured, mixed and L.P. (propane and butane) gases with appropriate conversion. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas suppller. Converslon must be done by a quallfled service technlclan. Gas converslon klt part numbers are llsted on the gas valve burner base.

E n Provide a rlgld gas supply line

of l/2-inch IPS pipe to ihe dryer’s location. If the total length of the supply line is more than 6.1 m

(20 feet), larger pipe will be needed. For L.P. gas usage, 3/8-inch, approved copper tubing may be used. Pipe-ioint comDounds suitable

fge

with L.P. gas should be used

F n If local codes and ordinances

permit, it is recommended that new flexible metal tubing, design-certified by the American Gas Association. be used for connecting the dryers to the gas supply line. (The gas feed pipe. which extends through the lower rear of each dryer, is provided with 3/8-inch male plpe thread.)

G w The SUDDIV line shall be equipped with a manual shutoff valve. This valve should be located in the same room as the dryers and should be in a location that allows ease of opening and closing. Do Not block access to shutoff valve.

H.

connec

main gas supply line, a combination of fittings must be used to obtaln an in-line connection to the dryers.

Copies of the standards listed above may be obtained from:

*American Gas Association

11515 Wilson Boulevard

Arlington, Virginla 22209

Page 3

Image 3
Contents Stacked Dryers -Hz Models InstructionsLncrkPT plugged tapplng Is required Before you startImportant Observe all governing codes and ordinances Protectlon from weather ProperParts owner Tools needed for installationInstallation Parts suppliedElectrical reauirements Kgrdmended groundingElectrlcal Shock Hazard Electrlcal ground Is required for Exhaust requirements It yoy q Recessed area and closet installationsTo connect exhaust duct straight out the back To connect exhaust duct to the right, left or bottomOr 6$ -minute Product dimensionsTo than e to a Timing camWith dryers in laundry area Now startAll connectlons must be wrench- tightened Move unit to its permanent locationPage If dryers do not Operate properly Move dryers to a New locationCheck the followlng to be sure that