RN42271MUK Rev8_Instruction Book 23/04/2013 13:42 Page 5
3Connect the appliance to a suitable mains outlet, and
switch on the socket. Turn the power switch ‚ on the base unit to ‘I’ (on) and the indicator will glow.
4The boiler ready indicator light „ situated above the ‘power switch’ ‚ will also illuminate, indicating the boiler is on its heating cycle and will go out when the required temperature is reached.
5Turn the temperature dial on the iron in a clockwise direction, select
6The iron’s temperature indicator light › goes off when the required temperature is reached.
7Depress the steam button ⁄ for 1 minute to clean the steam generating system (for first time use). It will be accompanied by a clicking noise which is quite normal.
8Begin first time ironing with an old towel. It takes about 1 minute to reach the required temperature.
9Press the steam button ⁄ for steam ironing.
10To switch the unit off, turn the power switch on the base unit to ‘O’ (OFF).
The spray unit
(certain models only)
The spray unit can be used at any time and does not affect any product settings.
Filling the spray unit
The spray feature ‰ is lightly secured to the handle. To fill the water tank, pull the spray unit forward using the two moulded lugs provided.
Remove the spray bottle  from the base of the pump and fill with water to the ‘MAX’ mark.
To replace the spray unit
Align the spray unit with the front of the iron.
Fit the bottom location leg into the slot at the front of the handle. Pivot the spray unit towards the iron, making sure it clips firmly in place.
ANTI-SCALE
SYSTEM
The
Replacing anti-scale filter
How often you need to replace the
If you iron more or less frequently, then you should alter the interval between refills accordingly.
Replacement anti-scale filters
To obtain replacement
•If a new filter is not available, you may continue operating the appliance but scale will build up in the system. Replace the used filter as soon as possible.
1Disconnect the appliance from the mains outlet.
2Slide out the tank and
remove the antiscale filter
E.
E
3Pull the plate from the end of the filter F.
4Remove the foam pad G
and slide out the spent antiscale sleeve H.
5Place the refill into the filter, reposition the foam pad and clip the plate onto the
filter, making sure it locks in position H.
H |
G |
F |
For details of other Morphy Richards products, please see our website: | 5 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|