DIAGNOSTIC TESTS AND ERROR CODES

Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x03

0x01

CP Bus parity - Control Store

0x01

An unexpected Check 1 condition was prema-

 

 

 

 

turely detected at the beginning of this test

 

 

 

 

 

 

 

 

0x02

CP Bus parity error was not set as expected

 

 

 

 

after attempting a read a Control Store loca-

 

 

 

 

tion previously written with bad parity

 

 

 

 

 

 

 

 

0x03

An unexpected Check 1 condition was pend-

 

 

 

 

ing after it should have been cleared

 

 

 

 

 

 

 

 

0x04

A CP bus parity error was not detected as

 

 

 

 

expected after a write/read operation on a

 

 

 

 

word of control store with forced bad parity

 

 

 

 

 

 

 

 

0x05

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x06

A CP bus parity error was not detected as

 

 

 

 

expected after reading a word previously writ-

 

 

 

 

ten with bad parity

 

 

 

 

 

 

 

 

0x07

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x10

A CP bus parity error was not detected after

 

 

 

 

writing byte 0 of a word with bad parity

 

 

 

 

 

 

 

 

0x11

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x12

A CP bus parity error was not detected after

 

 

 

 

reading byte 0 of a word which was previ-

 

 

 

 

ously written with bad parity

 

 

 

 

 

 

 

 

0x13

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x20

A CP bus parity error was not detected after

 

 

 

 

writing byte 1 of a word with bad parity

 

 

 

 

 

 

 

 

0x21

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x22

A CP bus parity error was not detected after

 

 

 

 

reading byte 1 of a word which was previ-

 

 

 

 

ously written with bad parity

 

 

 

 

 

 

 

 

0x23

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x30

A CP bus parity error was not detected after

 

 

 

 

writing byte2 of a word with bad parity

 

 

 

 

 

 

 

 

0x31

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES