DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-74 CG00000-011503 REV. A April 1997 Table F-22. Routine 81 - Manufacturing Test Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x81 * MFG tests 0xE0 DVL card not detected. This test cannot be
run without a DVL card connected to the DTC
card
0xE1 Drive NOT READY error. A working tape
must be loaded to run this test.
0x81 0x01 Get MFG Parameters - No error codes specific to this test
0x81 0x02 Display MFG Parameters - No error codes specific to this test
0x81 0x03 Clear Log Counters - No error codes specific to this test
0x81 0x04 Write BOT - EOT test 0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Cartridge WRITE PROTECT error. The car-
tridge must not be write protected for this test.
0x03 Buffer space request not granted for data
transfer.
0x04 Data transfer timed out.
0x05 Fatal error detected during data transfer.
0x06 Bad status reported on data transfer complete.
0x07 Logical EOT encountered during data trans-
fer.
0x08 Buffer flush timeout. Write from data buffer
to tape was not completed in the allocated
time.
0x09 Write data in error reported at end of data
transfer.
0x81 0x05 Read BOT - EOT test 0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Error detected while requesting buffer space
for data transfer.
0x03 Data transfer timeout error.
0x04 Error reported during data transfer.
0x05 Fatal error reported at completion of data
transfer.
0x06 Incorrect transfer length, retry required, or
recovered error and incorrect length reported
at end of data transfer.
DIAGNOSTIC TESTS
AND ERROR CODES