M2488 PRODUCT GUIDE

MAINTENANCE AND SERVICING

RS-232 User Interface Commands

Upon entering the Off-Line diagnostic mode, the command prompt

OFF-LINE DIAGNOSTIC COMMAND:

will appear. At the command prompt, the following commands are available.

a) Conventions used in this session:

All commands are case insensitive and may be abbreviated by entering only the first letter of the command. The lower case letters immediately following the first letter are optional.

Bold

Commands, options, variables, arguments, and user input appear in bold type-

 

face.

Italic

Names of variables to which values must be assigned are in italics.

< >

Input typed in a command line that does not appear on the screen (for example,

 

the return key) is shown within angle brackets.

[ ]

Optional input, such as command options, variables, and arguments, are

 

enclosed in square brackets.

b) RS-232 command set:

COMMAND

DESCRIPTION

VARIABLES/ARGUMENTS

 

 

 

Add r t [l]

Add a new test to the end of the

r -Routine number to be added. This number must be a valid rou-

 

test list.

tine number from the routines listed in the test registry (see List

 

 

command for more details).

 

 

t -Test number of the routine to be added. If an asterisk “*” is

 

 

entered, all tests for the given routine will be added.

 

 

l -Loop count, number of times to repeat this test. This number

 

 

must be in the range between 1 and 254. If 0 is entered, the test

 

 

will loop forever.

 

 

 

Delete n [x]

Delete a test from the list of

n -Delete node number n from list. The node number must be a

 

tests.

number in the range of node numbers in the current list. If an aster-

 

 

isk “*” is entered, then the entire list is deleted.

 

 

x - Delete to this end node. (Default is “*”; to the end of the list.)

 

 

 

Help (or ?)

Display RS-232 user interface

 

Help notes

command help. Entering this

 

Help macros

command displays the help

 

 

information shown in Figure 8-

 

 

1.

 

 

 

 

Insert n r t [l]

Insert a new test in the test list.

n -Node number to insert. This number must be in the range of

 

 

node numbers in the current list.

 

 

r -Routine number to be added. This number must be a valid rou-

 

 

tine number from the routines listed in the test registry (see List

 

 

command for more details).

 

 

t -Test number of the routine to be added. If an asterisk “*” is

 

 

entered, all tests for the given routine will be added.

 

 

l -Loop count, number of times to repeat this test. This number

 

 

must be in the range between 1 and 254. If 0 is entered, the test

 

 

will loop forever.

 

 

 

April 1997

CG00000-011503 REV. A

8-21

Page 331