DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-18 CG00000-011503 REV. A April 1997
0x04 0x08 RSVP Counters test - 2 byte mode 0x08 RSVP Interrupts not set as expected testing
counter 0
0x09 Register CECC data miscompare after reset-
ting Response Available testing counter 0
0x04 0x09 RSVP DBOB Interrupt test 0x01 Timeout waiting for Response Available after
setting DBOB Order Available
0x02 DBOB and RSVP Interrupt not set as
expected
Table F-7. Routine 5 - SDDP External Register Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x05 0x01 SDDP Host I/F Buffer Page Xreg
test 0x01 Buffer page register data miscompare
0x05 0x02 SDDP Host I/F Buffer Refresh
Xreg test 0x01 Buffer refresh register data miscompare
0x02 Error restoring buffer refresh register to initial
state
0x05 0x03 SDDP Host I/F Packet Header
Xregs test 0x01 Packet header register data miscompare
0x02 Error restoring packet header registers to ini-
tial state
Table F-8. Routine 6 - Data Buffer Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x06 0x01 Buffer RAM data bus bit test 0x01 Data bus bit miscompare
0x06 0x02 Buffer byte, half, word boundary
test 0x01 Full word read data miscompare
0x02 Half word read data miscompare
0x03 Byte read data miscompare
0x06 0x03 Buffer paging test 0x01 Buffer page data miscompare
Table F-6. Routine 4 - Read Signal Verification Processor Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES