DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-70 CG00000-011503 REV. A April 1997
0x80 0x02 Servo Diag: Photo sensors test 0x09 The cartridge mount sensor is on
0xE3 Servo command was not accepted; sense
information was built
0xE4 Servo command was accepted but failed to
complete within 60 seconds
0xE5 Servo error occurred that was not reported as
a diagnostic error.
0x80 0x03 Servo Diag: Loader test 0x01 Loader downward motion is too slow
0x02 Loader downward motion is too fast
0x03 Loader upward motion is too slow
0x04 Loader upward motion is too fast
0xE3 Servo command was not accepted; sense
information was built
0xE4 Servo command was accepted but failed to
complete within 60 seconds
0xE5 Servo error occurred that was not reported as
a diagnostic error.
0x80 0x04 Servo Diag: Threader test 0x01 Threader forward motion is too slow
0x02 Threader forward motion is too fast
0x03 Threader backward motion is too slow
0x04 Threader backward motion is too fast
0xE3 Servo command was not accepted; sense
information was built
0xE4 Servo command was accepted but failed to
complete within 60 seconds
0xE5 Servo error occurred that was not reported as
a diagnostic error.
0x80 0x05 Servo Diag: Tachometer test 0x01 The machine reel tachometer “A” is always
“1”
0x02 The machine reel tachometer “A” is always
“0”
0x03 The machine reel tachometer “B” is always
“1”
0x04 The machine reel tachometer “B” is always
“0”
0x05 The machine reel tachometer “A” and “B”
changed at the same time
Table F-19. Routine 80 - Servo Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS