DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

 

Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x03

0x01

CP Bus parity - Control Store

0x32

A CP bus parity error was not detected after

 

 

 

 

reading byte2 of a word which was previously

 

 

 

 

written with bad parity

 

 

 

 

 

 

 

 

0x33

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x40

A CP bus parity error was not detected after

 

 

 

 

writing byte 3 of a word with bad parity

 

 

 

 

 

 

 

 

0x41

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x42

A CP bus parity error was not detected after

 

 

 

 

reading byte 3 of a word which was previ-

 

 

 

 

ously written with bad parity

 

 

 

 

 

 

 

 

0x43

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x50

An unexpected Check 1 condition was

 

 

 

 

detected after attempting to write a word with

 

 

 

 

good parity to control store

 

 

 

 

 

0x03

0x02

CP Bus parity - SDDP

0x01

An unexpected Check 1 condition was prema-

 

 

 

 

turely detected at the beginning of this test

 

 

 

 

 

 

 

 

0x02

An unexpected Check 1 condition was

 

 

 

 

detected after reading the HDXC register in

 

 

 

 

the SDDP

 

 

 

 

 

 

 

 

0x03

A CP bus parity error was not detected as

 

 

 

 

expected after a SDDP register write opera-

 

 

 

 

tion with forced bad parity

 

 

 

 

 

 

 

 

0x04

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x05

A data miscompare was detected reading an

 

 

 

 

SDDP register previously written with bad

 

 

 

 

parity

 

 

 

 

 

 

 

 

0x06

An unexpected Check 1 condition was

 

 

 

 

detected after reading an SDDP register

 

 

 

 

 

 

 

 

0x07

An unexpected Check 1 condition was

 

 

 

 

detected after attempting to restore the con-

 

 

 

 

tents of the HDXC register

 

 

 

 

 

 

 

 

0x08

A data miscompare was detected when verify-

 

 

 

 

ing the contents of the HDXC register previ-

 

 

 

 

ously restored

 

 

 

 

 

 

 

 

0x09

An unexpected Check 1 condition was pend-

 

 

 

 

ing after read verification of the HDXC regis-

 

 

 

 

ter was completed

 

 

 

 

 

F-10

CG00000-011503 REV. A

April 1997

Page 410
Image 410
Fujitsu M2488 manual Diagnostic Tests and Error Codes