M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-51
0x20 * All Loop Write to Read tests 0xB3 CRRZ Xreg - expected data not equal to
received data
0xE0 Initialization Error - FDXS Xreg not zero fol-
lowing Transfer Cycle
0xE1 Initialization Error - TJ_WBEN Xreg not zero
following Write Clear
0xE2 Initialization Error - RBE Xreg not zero fol-
lowing Read Clear
0xE3 Initialization Error - RDE Xreg not zero fol-
lowing Read Clear
0xE4 Initialization Error - ETPA Xreg not zero fol-
lowing Read Clear
0xE5 Initialization Error - ETPB Xreg not zero fol-
lowing Read Clear
0xE6 Initialization Error - CRS Xreg not zero fol-
lowing Read Clear
0xE7 Initialization Error - WER Xreg not zero fol-
lowing Write Clear
0xE8 Initialization Error - TJ_PHOK Xreg not zero
following Read Clear
0xE9 Initialization Error -TJ_PRE Xreg not zero
following Read Clear
0xEA Initialization Error -TJ_POST Xreg not zero
following Read Clear
0xEB Initialization Error -TJ_REND Xreg not zero
following Read Clear
0x20 0x01 Loop Write to Read 0 test - 36
track 0x01 Failed to Detect IBG - check INLWR or
DBLK
0x02 Failed to Detect DBOB - check DBLK
0x03 Failed to Detect Phase OK
0x04 Failed to Detect Preamble - check RDSTT
0x05 Failed to Detect Postamble
0x06 Failed to Detect Read End
0x07 Phase OK not reset
0x08 Failed to Detect Write Block End
0x20 0x02 Loop Write to Read 0 test - 18
track 0x01 Failed to Detect IBG - check INLWR or
DBLK
Table F-16. Routine 20 - Loop Write to Read Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES