DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-22 CG00000-011503 REV. A April 1997
0x07 0x05 SPC MPU bus parity test 0x08 The SPC interrupt request could not be
cleared
0x09 CP bus parity error was not reported as
expected
0x0A Unexpected Check 1 condition was reported
after attempting to clear the Check 1 CP bus
parity error
Table F-10. Routine 8 - Formatter Counters Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x08 0x01 Formatter Counter 0 test 0x01 The Formatter Counter 0 count enable register
could not be cleared
0x02 A data miscompare occurred walking a one
through the Formatter Counter 0 high byte
count register
0x03 A data miscompare occurred walking a one
through the Formatter Counter 0 low byte
count register
0x04 Test Jump Carry Out bit for the high byte
count of Formatter Counter 0 was set prema-
turely before counter was started
0x05 An unexpected value was read in the count
enable register for Formatter Counter 0 after
the high byte counter finished running
0x06 The high byte count for Formatter Counter 0
did not contain the expected value after the
counter finished running
0x07 Test Jump Carry Out bit for the high byte
count of Formatter Counter 0 was not set as
expected after the counter finished running
0x08 Test Jump Carry Out bit for the low byte
count of Formatter Counter 0 was set prema-
turely before counter was started
0x09 An unexpected value was read in the count
enable register for Formatter Counter 0 after
the low byte counter finished running
Table F-9. Routine 7 - SCSI Protocol Controller Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS