DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

M2488 PRODUCT GUIDE

Table F-16. Routine 20 - Loop Write to Read Diagnostic Error Codes (Continued)

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x20

0x02

Loop Write to Read 0 test - 18

0x02

Failed to Detect DBOB - check DBLK

 

 

track

 

 

 

 

 

 

 

 

 

 

0x03

Failed to Detect Phase OK

 

 

 

 

 

 

 

 

0x04

Failed to Detect Preamble - check RDSTT

 

 

 

 

 

 

 

 

0x05

Failed to Detect Postamble

 

 

 

 

 

 

 

 

0x06

Failed to Detect Read End

 

 

 

 

 

 

 

 

0x07

Phase OK not reset

 

 

 

 

 

 

 

 

0x08

Failed to Detect Write Block End

 

 

 

 

 

0x20

0x03

LWR0 - EDRC Data - 36 track

0x01

Failed to Detect IBG - check INLWR or

 

 

 

 

DBLK

 

 

 

 

 

 

 

 

0x02

Failed to Detect DBOB - check DBLK

 

 

 

 

 

 

 

 

0x03

Failed to Detect Phase OK

 

 

 

 

 

 

 

 

0x04

Failed to Detect Preamble - check RDSTT

 

 

 

 

 

 

 

 

0x05

Failed to Detect Postamble

 

 

 

 

 

 

 

 

0x06

Failed to Detect Read End

 

 

 

 

 

 

 

 

0x07

Phase OK not reset

 

 

 

 

 

 

 

 

0x08

Failed to Detect Write Block End

 

 

 

 

 

 

 

 

0xB4

PF_BID Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xB5

PF_PSCT Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xB6

PFHD_ID Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xB7

PFOFST Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xB8

PFTRL_LN Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xB9

PF_FLAG Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xBA

PF_ALG Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xBB

PF13 Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

 

 

 

0xBC

PF14_15 Xreg - expected data not equal to

 

 

 

 

received data

 

 

 

 

 

F-52

CG00000-011503 REV. A

April 1997

Page 452