M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes (Continued)

 

 

 

 

 

 

ROUTINE

 

TEST

TITLE

ERROR

DESCRIPTION

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

0x12

 

0x01

SDDP-R20 buffer flush signal

0x03

 

when transferring data from the SPC send

 

 

 

test, mode 14h

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

 

 

 

0x04

 

when transferring data from the SPC send

 

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

 

 

xfer_phase.

 

 

 

 

 

 

 

 

 

 

 

0x05

 

host data transfer end of transfer was received

 

 

 

 

 

 

when not expected, check to see if flush is tied

 

 

 

 

 

 

high to some other signal.

 

 

 

 

 

 

 

 

 

 

 

0x06

 

host data transfer end of transfer was not

 

 

 

 

 

 

received when expected, check to see if flush

 

 

 

 

 

 

is tied low to some other signal.

 

 

 

 

 

 

 

 

 

 

 

0x07

 

All the data expected to be transferred out of

 

 

 

 

 

 

the SPC data fifo was not transferred to the

 

 

 

 

 

 

SDDP.

 

 

 

 

 

 

 

0x12

 

0x02

SDDP-R20 testing 64k sgc-i-

0x01

 

after a write diag operation was initialized in

 

 

 

mem, mode 14h

 

 

the spc chip, the SPC-status register did not

 

 

 

 

 

 

have one of the following:

 

 

 

 

 

 

SPC_data_trans_rdy, SPC_busy, or

 

 

 

 

 

 

SPC_data_reg_empty.

 

 

 

 

 

 

 

 

 

 

 

0x02

 

A non SUCCESS status was returned from

 

 

 

 

 

 

the function call rm_request_wrtbuffer.

 

 

 

 

 

 

 

 

 

 

 

0x03

 

when transferring data from the SPC send

 

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

 

 

 

0x04

 

when transferring data from the SPC send

 

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

 

 

xfer_phase.

 

 

 

 

 

 

 

 

 

 

 

0x05

 

when transferring data from the SPC send

 

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

 

 

 

0x06

 

when transferring data from the SPC send

 

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

 

 

xfer_phase.

 

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-39

Page 439