Fujitsu M2488 manual Appendix H MTU Diagnostic Specifications, Outline, HOW to Execute the Diag

Models: M2488

1 528
Download 528 pages 23.9 Kb
Page 483
Image 483

M2488 PRODUCT GUIDE

MTU DIAGNOSTIC SPECIFICATIONS

APPENDIX H

MTU DIAGNOSTIC SPECIFICATIONS

This appendix contains the Magnetic Tape Unit (MTU) DIAG Specifications (SCSI/RS-232C).

H-1 OUTLINE

For the M2488 test routines, such as DIAGs for the life test and evaluation, are provided in the servo microcode. Some routines that are used for factory automatic testing are provided as DIAGs.

This specifications describes how to activate the routines through SCSI or RS-232C interfaces, and how to output the execution result.

H-2 HOW TO EXECUTE THE DIAG

H-2.1 SCSI interface

Activate the MTU DIAG from the SCSI interface using the SEND DIAGNOSTIC command. Output the DIAG execution result data using the RECEIVE DIAGNOSTIC RESULTS command. The parameter for activating the MTU DIAG requires 480 bytes. When the DIAG has been completed, 512 bytes of data are transferred as the execution result.

H-2.2 RS-232C interface

The MTU DIAG is activated from the RS-232C interface using an exclusive command. The DIAG execution result data is also output to the RS-232C using the exclusive command. The MTU DIAG activation parameter requires 480 bytes. After the DIAG has been completed, 512 bytes of data is transferred with the results.

H-2.3 How to execute the DIAG for the MTU

The CP executes the DIAG for the MTU as follows:

1)Transfers the DIAG parameter to the servo microprocessor unit. (480 byte)

2)Activates the MTU DIAG.

3)Receives the DIAG result data.(512 byte)

For these commands, refer to the Drive Controller-Drive Firmware Interface Specification.

H-3 M2488 DIAG STRUCTURE

The M2488 diagnostic tests can be classified into five types:

1.RD/WRT: Ten diagnostic tests to check read and write

2.LD/UNLD: Two diagnostic tests to check loading and unloading

3.ACL TEST: Two diagnostic tests to check the autoloader

4.TESTMODE: Diagnostic test to measure operations

5.COMBINATION: Running test by combining up to ten commands These tests are presented in the following tables.

April 1997

CG00000-011503 REV. A

H-1

Page 483
Image 483
Fujitsu manual Appendix H MTU Diagnostic Specifications, Outline, HOW to Execute the Diag, M2488 Diag Structure