M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-15
0x04 0x01 RSVP Internal Registers test 0x0E Data miscompare attempting to set RSVP reg-
ister TIMR to 0x55
0x01 Timeout waiting for RSVP Response Avail-
able after setting DSG0 Order Available
0x02 RSVP Alert Interrupt not set as expected after
setting DSG0 Order Available
0x03 Timeout waiting for RSVP Response Avail-
able after setting DSG1 Order Available
0x04 RSVP Alert Interrupt not set as expected after
setting DSG1 Order Available
0x04 0x02 RSVP External Registers test 0x05 Timeout waiting for RSVP Response Avail-
able after setting RDOP Order Available
0x06 RSVP Alert Interrupt not set as expected after
setting RDOP Order Available
0x07 Timeout waiting for RSVP Response Avail-
able after setting FCNT Order Available
0x08 RSVP Alert Interrupt not set as expected after
setting FCNT Order Available
0x09 Timeout waiting for RSVP Response Avail-
able after setting FCNT.B Order Available
0x0A RSVP Alert Interrupt not set as expected after
setting FCNT.B Order Available
0x0B Unable to reset all register FCNT bits
0x0C Timeout waiting for RSVP Response Avail-
able after setting CECC Order Available
0x0D RSVP Alert Interrupt not set as expected after
setting CECC Order Available
0x04 0x03 RSVP Counters test -2 frame 0x01 Carry counter error
0x02 Timeout waiting for Response Available after
setting CECC Order Available
0x03 RSVP Interrupts not set as expected
0x04 Register CECC data miscompare after clear-
ing Response Available
0x04 0x04 RSVP Counters test -4 frame 0x01 Carry counter error
0x02 Timeout waiting for Response Available after
setting CECC Order Available
0x03 RSVP Interrupts not set as expected
Table F-6. Routine 4 - Read Signal Verification Processor Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES