M2488 PRODUCT GUIDE

MAINTENANCE AND SERVICING

Off-Line diagnostic command: help

- Diagnostic Help: Overview -----------------------------------------------------------------

COMMANDS:

 

 

Add r t [l] ----------------

> Add to test list

Continue -----------------

> Continue running the current test list

Delete n [x] --------------

> Delete a test, n="*" clears the entire list

Help? [notesmacros] ->

Diagnostic help information

Insert n r t [l] ------------

>

Insert test at node 'n' in list

List [n] [x] --------------

>

List tests in Test List

List Registry [r] [t] ---

>

List tests in Test Registry

List Errors --------------

>

List Error history

Node [n] [l] -------------

>

Set loop count to ‘l’ at ‘n’

Options [o][+-][ces]

--->Options for all tests, or loop count at node 'n'

Quit ----------------------

>

Quit Diagnostics

Run [#] ------------------

>

Run entire test list # times [1=default, 0=forever]

KEY:

 

 

r = routine number (HEX)

t = test number (HEX)

l = loop count byte, 1 (default) to 254 times, or 0 to loop test forever

n = node number

 

x = end node number

+c = continue on error

 

-c = stop on error

+e = display errors

 

-e = suppress error display

+s = display status

 

-s = suppress status

--------------------------------------------------------------------------------------------------------

Off-Line diagnostic command: help macros

-Diagnostic Help: Macros -----------------------------------------------------------------------

Macros are an easy way to build and run a list of diagnostics routines and

tests. Macros are executed by entering "RUN" [macro name] [run count]

VALID MACRO NAMES:

ACL = ACL/FACL test without magazine ACL_MAG = ACL/FACL test with magazine

ACL_ALL = ACL/FACL test list - both with and without magazine COMB = All LWR “In-line” tests

MTC = Controller test list

MTU = Drive test without cartridge MTU_CART = Drive test with cartridge

MTU_ALL = Drive test list - both with and without cartridge LOAD = Load cartridge

UNLOAD = Unload cartridge

--------------------------------------------------------------------------------------------------------

Off-Line diagnostic command: help notes

-Diagnostic Help: Notes -------------------------------------------------------------------------

NOTES:

1.Only the first letter (case insensitive) of each command is required

2.Routine, Test, and Options numbers are always entered in hexadecimal

3.Loop counts and Node numbers are decimal by default (prefix '0x' for Hex)

4.The wildcard "*" may be used to select all routines, tests, etc.

5.Multiple commands per line may be entered using a semicolon (;) separator

6.To abort running tests, enter [RETURN] or press and hold the RESET button

7.The test list Options may also be entered as a hexadecimal number:

Options [o]

where, o = options byte (HEX): bit 0 = 0x01 -> continue on error

(NOTE: These settings are bit

bit 5 =0x20 -> suppress errors

significant)

bit 6 = 0x40 -> suppress status

Figure 8-1. Help Information Display

April 1997

CG00000-011503 REV. A

8-23

Page 333