M2488 PRODUCT GUIDE

 

 

 

 

 

 

TAPE UNIT SCSI COMMANDS

 

 

Table 4-38. Log Sense Page 03h, Error Counter Page - Read (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BITS

 

 

 

 

 

DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

7

6

5

4

 

3

 

2

1

0

VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

Parameter Length

 

 

 

08h

 

 

 

 

 

 

 

 

 

20-

MSB

Number of Read Data Checks Detected By Firmware (i.e. Errors

 

 

 

 

27

 

 

corrected with possible delays)

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL ERRORS CORRECTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-

MSB

 

 

Parameter Code

 

 

 

0003h

 

 

29

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

DU

DS=1

TSD=1

ETC=0

 

TMC=0

 

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

 

 

 

Parameter Length

 

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-

MSB

Total Read Errors Corrected by Internal Error recovery

 

 

 

 

39

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL READ (FORWARD) BYTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40-

MSB

 

 

Parameter Code

 

 

 

0005h

 

 

41

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

DU

DS=1

TSD=1

ETC=0

 

TMC=0

 

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

 

 

 

Parameter Length

 

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44-

MSB

 

Total Bytes Read from Tape

 

 

 

 

 

 

51

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES TRANSFERRED TO INITIATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-

MSB

 

 

Parameter Code

 

 

 

9010h

 

 

53

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54

DU

DS=1

TSD=1

ETC=0

 

TMC=0

 

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

 

Parameter Length

 

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56-

MSB

 

Total Bytes Transferred to Initiator

 

 

 

 

 

63

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL READ BLOCKS THAT WERE RECORDED IN EDRC FORMAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-

MSB

 

 

Parameter Code

 

 

 

9011h

 

 

65

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66

DU

DS=1

TSD=1

ETC=0

 

TMC=0

 

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

 

 

 

Parameter Length

 

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68-

MSB

 

Total Blocks Read (excluding filemarks)

 

 

 

 

 

75

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL TAPE MARKS READ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

76-

MSB

 

 

Parameter Code

 

 

 

9012h

 

 

77

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

78

DU

DS=1

TSD=1

ETC=0

 

TMC=0

 

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

April 1997

CG00000-011503 REV. A

4-41

Page 123
Image 123
Fujitsu M2488 Total Errors Corrected, Total Read Forward Bytes, Bytes Transferred to Initiator, Total Tape Marks Read