DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

 

Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes (Continued)

 

 

 

 

 

 

ROUTINE

 

TEST

TITLE

ERROR

DESCRIPTION

 

CODE

 

 

 

 

 

 

 

 

 

 

 

0x12

 

0x06

SDDP-R20 testing expansion sgd-

0x04

All the data expected to be transferred from

 

 

 

de, mode 00h

 

the SPC data_fifo to the SPC receive_buffer

 

 

 

 

 

was not transferred.

 

 

 

 

 

 

 

 

 

 

0x05

A non SUCCESS status was returned from

 

 

 

 

 

the function call rm_host_rd_complt. A error

 

 

 

 

 

was detected in the SDDP_HI-hdxs register.

 

 

 

 

 

 

 

 

 

 

0x07

A byte for byte miscompare was detected on

 

 

 

 

 

the data bytes stored in the SPC receive

 

 

 

 

 

buffer.

 

 

 

 

 

 

0x12

 

0x07

SDDP-R20 testing expansion sgc-

0x01

after a write diag operation was initialized in

 

 

 

ce, mode 10h

 

the spc chip, the SPC-status register did not

 

 

 

 

 

have one of the following:

 

 

 

 

 

SPC_data_trans_rdy, SPC_busy, or

 

 

 

 

 

SPC_data_reg_empty.

 

 

 

 

 

 

 

 

 

 

0x02

when transferring data from the SPC send

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

 

 

0x03

when transferring data from the SPC send

 

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

 

xfer_phase.

 

 

 

 

 

 

 

 

 

 

0x04

A non SUCCESS status was returned from

 

 

 

 

 

the function call rm_request_wrtbuffer.

 

 

 

 

 

 

 

 

 

 

0x05

All the data expected to be transferred out of

 

 

 

 

 

the SPC data fifo was not transferred to the

 

 

 

 

 

SDDP.

 

 

 

 

 

 

 

 

 

 

0x06

A non SUCCESS status was returned from

 

 

 

 

 

the function call rm_host_wrt_cmplt. A error

 

 

 

 

 

was detected in the SDDP_HI-hdxs register.

 

 

 

 

 

 

 

 

 

 

0x07

A byte for byte miscompare was detected on

 

 

 

 

 

the data bytes stored in the data_buffer.

 

 

 

 

 

 

0x12

 

0x08

SDDP-R20 Read flush testing,

0x01

A host data path end of transfer was not

 

 

 

mode 00h

 

detected in the allotted time.

 

 

 

 

 

 

 

 

 

 

0x02

when transferring data from the SPC data_fifo

 

 

 

 

 

to the SPC receive_buffer, the SPC-ssig regis-

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

 

 

0x03

when transferring data from the SPC data_fifo

 

 

 

 

 

to the SPC receive_buffer, the SPC-ssig regis-

 

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

 

xfer_phase.

 

 

 

 

 

 

F-42

CG00000-011503 REV. A

April 1997

Page 442
Image 442
Fujitsu M2488 manual Diagnostic Tests and Error Codes