M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-1
APPENDIX FDIAGNOSTIC TESTS AND ERROR CODES
Table F-1 lists all of the diagnostic tests in the Diagnostic Test Registry for the Tasked Go/No-Go
mode, the On-Line mode, and the Off-Line mode. An ‘x’ indicates in which diagnostic modes the test
may be run The ‘MFG’ column indicates tests available when FACTORY MODE is enabled. Table F-
3 through Table F-25 list and describe the diagnostic error codes by the routine and test numbers.
Table F-1. Diagnostic Test Registry for all Diagnostic Modes
ROUTINE TEST DIAGNOSTIC MODES TITLE
OFF-LINE ON-LINE GO/NO-GO MFG
01 01 x Control store data bus test
01 02 x Control store byte boundary test
01 03 x Control store half word boundary test
01 04 x Control store address bus test
01 05 x Control store incrementing pattern test
01 06 x Control store data pattern 0xAA test
01 07 x Control store data pattern 0x55 test
01 08 x Control store walking 0xFFs test
02 01 x IRC initialization
02 02 x IRC to PCC interrupt test
02 03 x Timer 0 interrupt test
02 04 x Timer 1 interrupt test
02 05 x Check 1 interrupt test
02 06 x IRC test cleanup/exit
0301xxxxCP Bus parity - Control Store
0302xxxxCP Bus parity - SDDP
03 03 x x x CP Bus parity - SPC
0401xxxxRSVP Internal registers test
0402xxxxRSVP External registers test
0403xxxxRSVP Counters test - 2 frame
0404xxxxRSVP Counters test - 4 frame
0405xxxxRSVP Counters test - 8 frame
0406xxxxRSVP Counters test - 16 frame
0407xxxxRSVP Counters test - single byte mode