DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-8 CG00000-011503 REV. A April 1997
Table F-4. Routine 2 - Interrupt Request Controller Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x02 0x01 IRC initialization 0x01 Processor in invalid register window
0x02 Pending interrupt detected at IRC input
0x03 Pending interrupt latched in IRC
0x02 0x02 IRC to PCC interrupt test 0x01 Expected interrupt(s) not detected in IRC
0x02 No interrupt detected by processor
0x03 Expected interrupt not detected in processor
0x02 0x03 Timer 0 interrupt test 0x01 Timer 0 interrupt not detected
0x02 Incorrect interrupt detected
0x02 0x04 Timer 1 interrupt test 0x01 Timer 1 interrupt not detected
0x02 Incorrect interrupt detected
0x02 0x05 Check 1 interrupt test 0x01 Pending interrupt detected
0x02 CP bus timeout not detected
0x03 Check 1 interrupt not detected
0x04 Incorrect interrupt detected
0x05 Interrupt(s) could not be cleared
DIAGNOSTIC TESTS
AND ERROR CODES