DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-14 CG00000-011503 REV. A April 1997 Table F-6. Routine 4 - Read Signal Verification Processor Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x04 * RSVP Routine Initialization 0xE0 Initialization timeout waiting for RSVP to
reach the RSVP idle loop
0xE1 RSVP reported incorrect status after being
reset
0xE2 RSVP failed to clear Response Available in
the allocated time
0xE3 RSVP failed to set Response Available in the
allocated time
0xE4 RSVP Alert Interrupt not set as expected
0xE5 RSVP failed to set data transfer or timer regis-
ters as expected
0x04 0x01 RSVP Internal Registers test 0x01 RSVP failed to set control register RCTL as
expected
0x02 RSVP failed to clear control register RCTL as
expected
0x03 Data miscompare attempting to set RSVP reg-
ister RDME
0x04 Data miscompare attempting to clear RSVP
register RDME
0x05 Data miscompare attempting to set RSVP reg-
ister SNDA to 0x55
0x06 Data miscompare attempting to set RSVP reg-
ister SNDA to 0xAA
0x07 Data miscompare attempting to clear RSVP
register SNDA
0x08 Data miscompare attempting to set RSVP reg-
ister SNDB to 0x55
0x09 Data miscompare attempting to set RSVP reg-
ister SNDB to 0xAA
0x0A Data miscompare attempting to clear RSVP
register SNDB
0x0B Data miscompare attempting to set RSVP reg-
ister SNDC to 0x55
0x0C Data miscompare attempting to set RSVP reg-
ister SNDC to 0xAA
0x0D Data miscompare attempting to clear RSVP
register SNDC
DIAGNOSTIC TESTS
AND ERROR CODES