0x03 0x03 CP Bus parity - SPC 0x04 An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x05 An expected CP bus parity was not detected
after attempting to read an SPC register with
SPC parity inverted
0x06 An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x07 An unexpected Check 1 condition was
detected
0x10 Initialization of the SPC chip failed
0x20 SPC interrupt request was not generated dur-
ing SPC Diagnostic initialization
0x21 An SPC interrupt was not detected in the
Interrupt Request Controller (IRC) during
SPC Diagnostic initialization
0x22 The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
0x23 The SPC interrupt/step code did not report
command complete as expected
0x24 The SPC interrupt request could not be
cleared
0x30 An SPC interrupt request was not generated
by the SPC during diagnostic test
0x31 An SPC interrupt was not detected in the
Interrupt Request Controller (IRC) during
SPC Diagnostic initialization
0x32 The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
0x33 The SPC interrupt/step code did not report a
Register Parity error as expected
0x34 The SPC interrupt request could not be
cleared
0x40 An SPC interrupt request was not generated
by the SPC during diagnostic test
0x41 An expected SPC interrupt was not detected
in the Interrupt Request Controller (IRC)
0x42 The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS