Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x03

0x03

CP Bus parity - SPC

0x04

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x05

An expected CP bus parity was not detected

 

 

 

 

after attempting to read an SPC register with

 

 

 

 

SPC parity inverted

 

 

 

 

 

 

 

 

0x06

An unexpected Check 1 condition was pend-

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

0x07

An unexpected Check 1 condition was

 

 

 

 

detected

 

 

 

 

 

 

 

 

0x10

Initialization of the SPC chip failed

 

 

 

 

 

 

 

 

0x20

SPC interrupt request was not generated dur-

 

 

 

 

ing SPC Diagnostic initialization

 

 

 

 

 

 

 

 

0x21

An SPC interrupt was not detected in the

 

 

 

 

Interrupt Request Controller (IRC) during

 

 

 

 

SPC Diagnostic initialization

 

 

 

 

 

 

 

 

0x22

The SPC interrupt was inadvertently cleared

 

 

 

 

when the Interrupt Request Controller was

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0x23

The SPC interrupt/step code did not report

 

 

 

 

command complete as expected

 

 

 

 

 

 

 

 

0x24

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0x30

An SPC interrupt request was not generated

 

 

 

 

by the SPC during diagnostic test

 

 

 

 

 

 

 

 

0x31

An SPC interrupt was not detected in the

 

 

 

 

Interrupt Request Controller (IRC) during

 

 

 

 

SPC Diagnostic initialization

 

 

 

 

 

 

 

 

0x32

The SPC interrupt was inadvertently cleared

 

 

 

 

when the Interrupt Request Controller was

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0x33

The SPC interrupt/step code did not report a

 

 

 

 

Register Parity error as expected

 

 

 

 

 

 

 

 

0x34

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0x40

An SPC interrupt request was not generated

 

 

 

 

by the SPC during diagnostic test

 

 

 

 

 

 

 

 

0x41

An expected SPC interrupt was not detected

 

 

 

 

in the Interrupt Request Controller (IRC)

 

 

 

 

 

 

 

 

0x42

The SPC interrupt was inadvertently cleared

 

 

 

 

when the Interrupt Request Controller was

 

 

 

 

cleared

 

 

 

 

 

F-12