Table 3. Light Path Diagnostics (continued)
Lit LED | Cause | Action |
|
|
|
Power module | A critical error has occurred in the power | Replace the module. If your BladeCenter unit |
error | module. | has a redundant module for this power module, |
|
| the BladeCenter unit continues to function |
|
| using the redundant module. |
|
|
|
Blower module |
|
|
|
|
|
The blower has failed or is operating too | Replace the blower module as soon as | |
error | slowly. | possible to regain cooling redundancy. The |
|
| BladeCenter unit continues to function. The |
|
| redundant blower module provides cooling to |
|
| the BladeCenter unit and blades. |
|
|
|
I/O module |
|
|
|
|
|
I/O module error | A critical error has occurred in the I/O module. | Replace the module. |
|
|
|
Temperature error messages
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action | |
|
|
|
Power supply x temperature fault | 1. | Ensure that the system is being properly cooled; see “System |
| ||
|
| reliability considerations” on page 32. |
| 2. | Replace power supply x. |
|
|
|
Power supply x temperature warning | 1. | Ensure that the system is being properly cooled; see “System |
| ||
|
| reliability considerations” on page 32. |
| 2. | Replace power supply x. |
|
|
|
Switch x temperature fault | 1. | Ensure that the system is being properly cooled; see “System |
| ||
|
| reliability considerations” on page 32. |
| 2. | Replace I/O module x. |
|
| |
System over abbient temperature | Ensure that the system is being properly cooled; see “System | |
| reliability considerations” on page 32. | |
|
| |
Switch x temperature fault | Ensure that the system is being properly cooled; see “System | |
| reliability considerations” on page 32. | |
|
|
|
Blower error messages
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action |
|
|
Blower x outside recommended speed | Replace blower x. |
|
|
Blower x failure | Replace blower x. |
|
|
Blower x fault | Replace blower x. |
|
|