IBM Type 8677, Type 1881 manual Management-module error messages

Models: Type 8677 Type 1881

1 152
Download 152 pages 25.71 Kb
Page 85
Image 85

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

Switch module%d IP configuration was

Information only. Take action as required.

changed

 

 

 

ENET [X] DHCP HSTN=X, DN=X, IP @=

Ethernet configuration information. Take action as required.

XXX.XXX.XXX.XXXGW @=

 

XXXX.XXX.XXX.XXX, SN=

 

XXX,XXX,XXX,XXX, DNS1@=

 

XXX.XXX.XXX.XXX

 

 

 

ENET [X] IP Cfg:HstName= XXXX, IP@=

Ethernet configuration information. Take action as required.

XXX.XXX.XXX.XXX ,GW@=

 

XXX.XXX.XXX.XXX, NetMsk=

 

XXX.XXX.XXX.XXX Switch module x was

 

installed

 

 

 

LAN: Ethernet [x] interface is no longer

Check cables to I/O module.

active

 

 

 

LAN: Ethernet [x] interface now longer

Information only. Take action as required.

active

 

 

 

Management-module error messages

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

Application posted alert to ASM

The alert button on the Web interface was tested. Information only.

 

Take action as required.

 

 

System log 75% full

Information only. Take action as required.

 

 

System log full

Information only. Take action as required.

 

 

Management module network

Information only. Take action as required.

initialization complete

 

 

 

 

Remote login successful. Login ID

Information only. Take action as required.

 

 

ASM reset was caused by restoring

The management-module assembly was reset after restoring the

default values

default settings. Information only. Take action as required.

 

 

ASM reset was initiated by the user

Information only. Take action as required.

 

 

 

Pushbutton reset activated: Ethernet

1.

Reseat the management module.

configuration reset to default values and

2.

Reflash the management-module firmware.

MM ASM reset due to watchdog timeout

3.

Replace the management module.

 

 

 

 

ASM reset due to XXXXX, instruction

1.

Reseat the management module.

fault: XXXXXXXX YYYYYYYY ZZZZZZ

2.

Reflash the management-module firmware.

 

 

3.

Replace the management module.

 

 

ASM reset reason unknown

Information only.

 

 

Possible ASM reset occurred reason

Information only.

unknown

 

 

 

 

Remote access attempt failed. Invalid

Failed attempt to log into the management module.

userid or password received. User is

 

 

XXX from CMD mode client at

 

 

IP@=XXX.XXX.XXX.XXX

 

 

 

 

 

Chapter 6. Symptom-to-FRU index 75

Page 85
Image 85
IBM Type 8677, Type 1881 Management-module error messages, Ethernet configuration information. Take action as required