Light Path Diagnostics table

The system-error LED on the system LED panel is lit when certain system errors occur. If the system-error LED on your BladeCenter unit is lit, use the following table to help determine the cause of the error and the action you should take.

Table 3. Light Path Diagnostics

Lit LED

Cause

Action

 

 

 

BladeCenter system LED panel

 

 

 

 

Location

A condition has occurred in this BladeCenter

Look for any information or error LEDs on the

 

unit that has caused the remote system

system-LED panel, the modules, and the

 

management to identify this BladeCenter unit

blades in the this BladeCenter unit, and follow

 

as needing attention.

the instructions in this table for those LEDs.

 

 

 

Over-temperature

The system temperature has exceeded a

1. Check to see if a blower module has failed.

 

threshold level.

 

If it has, replace the blower module as

 

 

 

 

soon as possible to regain redundancy.

 

 

2. Make sure the room temperature is not too

 

 

high. (See “Features and specifications” on

 

 

page 5 for temperature information.)

 

 

3. Check to see if a blade server has a

 

 

temperature LED lit. If it has, see the

 

 

documentation that comes with the blade

 

 

server.

 

 

4. Make sure there is a blade, module, or filler

 

 

plugged in each bay.

 

 

If the problem remains, have the system

 

 

serviced.

 

 

 

Information

A noncritical event has occurred that should be

Check the error log for the messages. Check

 

looked at, such as the wrong I/O module

the LEDs on the BladeCenter unit and the

 

inserted in a bay, or power needs that exceed

blade servers to isolate the component.

 

the capacity of power modules currently

 

 

installed.

 

 

 

 

System error

A critical system error has occurred, such as

1. Check the error log for messages.

 

non-redundancy on the power modules or a

 

2. Look for an error LED on the modules and

 

system error in a blade.

 

blades to locate the component.

 

 

 

 

v If the error LED is on a module, follow

 

 

the instructions for the module in this

 

 

table.

 

 

v If the error LED is on a blade, see the

 

 

documentation that comes with the

 

 

blade.

 

 

 

Management module

 

 

 

 

Management-

A critical error has occurred in the

Unplug the management module and reinsert

module error

management module.

it, then, restart the BladeCenter unit. If the

 

 

problem remains, replace the management

 

 

module.

 

 

 

Management-

After adding or restarting an Ethernet switch

You must wait until the Ethernet switch module

module Web

module through the management-module Web

completes POST. After Ethernet switch module

interface to

interface, the Web page does not refresh. You

POST is complete, you will be able to connect

Ethernet switch

will also be unable to connect to the Ethernet

to the Ethernet switch module.

module does not

switch module through the Telnet interface.

 

refresh

 

 

 

 

 

Power module

 

 

 

 

 

Chapter 6. Symptom-to-FRU index 71

Page 81
Image 81