Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

Remote access attempt failed. Invalid

Failed attempt to log into the management module.

userid or password received. User is

 

XXX from WEB browser

 

IP@=XXX.XXX.XXX.XXX

 

 

 

DHCP [X] failure, no IP @ assigned (retry

Failed to get IP address by DHCP server. Check the DHCP server

X), rc=X

connection and settings.

 

 

LAN: Command mode tamper triggered.

Unsuccessful attempt to access the management module in

Possible break in attempt.

command mode. Information only. Take action as required.

 

 

LAN: WEB server tamper delay

Unsuccessful attempt to access the management module in

triggered. Possible break in attempt.

command mode. Information only. Take action as required.

 

 

System log cleared.

Information only. Take action as required.

 

 

Bus error messages

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

 

Failure reading I2C device. Check

1.

Reset the management module.

devices on bus 1.

2.

Reseat the management module.

 

 

3.

Reflash the management module.

 

4.

Replace the management module.

 

 

 

Failure reading I2C device. Check

1.

Reset the management module.

devices on bus 2.

2.

Reseat the management module.

 

 

3.

Replace the management module.

 

4.

Replace the midplane.

 

 

 

Failure reading I2C device. Check

1.

Reseat the power modules.

devices on bus 3.

2.

Reseat the management module.

 

 

3.

Replace the power modules.

 

4.

Replace the management module.

 

5.

Replace the midplane.

 

 

 

Failure reading I2C device. Check

1.

Reseat the management module.

devices on bus 4.

2.

Reseat the cables connected to the front panel customer interface

 

 

 

card.

 

3.

Reseat the cables connected to the rear panel customer interface

 

 

card.

 

4.

Replace the front panel customer interface card.

 

5.

Replace the rear panel customer interface card.

 

6.

Replace the management module.

 

7.

Replace the midplane.

 

 

 

76BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide

Page 86
Image 86
IBM Type 1881, Type 8677 manual Bus error messages