Power error messages
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action | ||
|
| ||
Power module 3 or 4 is required to | Ensure power modules 3 and 4 are installed and connected to ac | ||
power blades 7 to 14 | power. | ||
|
| ||
Power supply x fault | Replace power module x. | ||
|
| ||
Power supply x 12V over voltage fault | Replace power module x. | ||
|
|
| |
Power supply x 12V over current fault | 1. | An over current condition is typically caused by an external | |
| |||
|
| load fault. Attempt to restart the faulted power module by | |
|
| removing ac to the system components one at a time to isolate | |
|
| the failing component. | |
| 2. | Replace power module. | |
|
| ||
Power supply x 12V under voltage fault | Replace power module x. | ||
|
| ||
Power supply x 12V current fault | Replace power module x. | ||
|
| ||
Power supply x DC good fault | Replace power module x. | ||
|
| ||
Power supply x removed | Reinstall power supply x. | ||
|
|
| |
System over recommended voltage for | 1. | Reseat the management module. | |
+12V | |||
2. | Reseat the power modules. | ||
| |||
| 3. | Replace the power modules. | |
| 4. | Replace the management module. | |
|
|
| |
System over recommended voltage for | 1. | Reseat the management module. | |
+1.8V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System over recommended voltage for | 1. | Reseat the management module. | |
+2.5V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System over recommended voltage for | 1. | Reseat the management module. | |
+3.3V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System over recommended voltage for | 1. | Reseat the management module. | |
5V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System over recommended voltage for | 1. | Reseat the management module. | |
+5V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System under recommended voltage for | 1. | Reseat the management module. | |
+12V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System under recommended voltage for | 1. | Reseat the management module. | |
+1.8V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System under recommended voltage for | 1. | Reseat the management module. | |
+2.5V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System under recommended voltage for | 1. | Reseat the management module. | |
3.3V | |||
2. | Replace the management module. | ||
| |||
|
|
| |
System under recommended voltage for | 1. | Reseat the management module. | |
5V | |||
2. | Replace the management module. | ||
| |||
|
|
|