IBM Type 8677, Type 1881 manual Power error messages

Models: Type 8677 Type 1881

1 152
Download 152 pages 25.71 Kb
Page 83
Image 83

Power error messages

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

Power module 3 or 4 is required to

Ensure power modules 3 and 4 are installed and connected to ac

power blades 7 to 14

power.

 

 

Power supply x fault

Replace power module x.

 

 

Power supply x 12V over voltage fault

Replace power module x.

 

 

 

Power supply x 12V over current fault

1.

An over current condition is typically caused by an external

 

 

 

load fault. Attempt to restart the faulted power module by

 

 

removing ac to the system components one at a time to isolate

 

 

the failing component.

 

2.

Replace power module.

 

 

Power supply x 12V under voltage fault

Replace power module x.

 

 

Power supply x 12V current fault

Replace power module x.

 

 

Power supply x DC good fault

Replace power module x.

 

 

Power supply x removed

Reinstall power supply x.

 

 

 

System over recommended voltage for

1.

Reseat the management module.

+12V

2.

Reseat the power modules.

 

 

3.

Replace the power modules.

 

4.

Replace the management module.

 

 

 

System over recommended voltage for

1.

Reseat the management module.

+1.8V

2.

Replace the management module.

 

 

 

 

System over recommended voltage for

1.

Reseat the management module.

+2.5V

2.

Replace the management module.

 

 

 

 

System over recommended voltage for

1.

Reseat the management module.

+3.3V

2.

Replace the management module.

 

 

 

 

System over recommended voltage for

1.

Reseat the management module.

5V

2.

Replace the management module.

 

 

 

 

System over recommended voltage for

1.

Reseat the management module.

+5V

2.

Replace the management module.

 

 

 

 

System under recommended voltage for

1.

Reseat the management module.

+12V

2.

Replace the management module.

 

 

 

 

System under recommended voltage for

1.

Reseat the management module.

+1.8V

2.

Replace the management module.

 

 

 

 

System under recommended voltage for

1.

Reseat the management module.

+2.5V

2.

Replace the management module.

 

 

 

 

System under recommended voltage for

1.

Reseat the management module.

3.3V

2.

Replace the management module.

 

 

 

 

System under recommended voltage for

1.

Reseat the management module.

5V

2.

Replace the management module.

 

 

 

 

Chapter 6. Symptom-to-FRU index 73