Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

 

System is under recommended voltage

1.

Reseat the management module.

for +5V

2.

Replace the management module.

 

 

 

System running nonredundant power

Ensure that power modules 1 and 2 are installed and operating

 

correctly. If blade servers are installed in bay 7 or higher, ensure

 

that power modules 3 and 4 are installed and working correctly.

 

 

 

Blade server error messages

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

Blade server x was installed

Information only. Take action as required.

 

 

Blade server x was removed

Information only. Take action as required.

 

 

Received an [xxx] alert from an

Ensure that all blade servers in the blade center are supported by

unsupported ISMP type xxxx, via the

the management module.

interconnect network

 

 

 

KVM error message

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

 

Error encountered switching KVM owner,

1.

Reseat the blade server.

see system error log

2.

Reseat the management module.

 

 

3.

Reflash the blade server H8 firmware.

 

4.

Replace the blade server.

 

5.

Replace the management module.

 

6.

Replace the midplane.

 

 

 

I/O module error messages

Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.

Message

Action

 

 

Switch fault x

1. Reseat I/O module x.

 

 

2. Replace I/O module x.

 

 

Switch module x was removed

Information only. Take action as required.

 

 

Switch module x was installed

Information only. Take action as required.

 

 

Switch module x was powered on

Information only. Take action as required.

 

 

Switch module x was powered on

Information only. Take action as required.

 

 

Switch System running nonredundant

Information only. Take action as required.

switch modules

 

 

 

74BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide

Page 84
Image 84
IBM Type 1881, Type 8677 manual Blade server error messages, KVM error message, Module error messages