Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action | ||
|
|
| |
System is under recommended voltage | 1. | Reseat the management module. | |
for +5V | |||
2. | Replace the management module. | ||
| |||
|
| ||
System running nonredundant power | Ensure that power modules 1 and 2 are installed and operating | ||
| correctly. If blade servers are installed in bay 7 or higher, ensure | ||
| that power modules 3 and 4 are installed and working correctly. | ||
|
|
|
Blade server error messages
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action |
|
|
Blade server x was installed | Information only. Take action as required. |
|
|
Blade server x was removed | Information only. Take action as required. |
|
|
Received an [xxx] alert from an | Ensure that all blade servers in the blade center are supported by |
unsupported ISMP type xxxx, via the | the management module. |
interconnect network |
|
|
|
KVM error message
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action | |
|
|
|
Error encountered switching KVM owner, | 1. | Reseat the blade server. |
see system error log | 2. | Reseat the management module. |
| ||
| 3. | Reflash the blade server H8 firmware. |
| 4. | Replace the blade server. |
| 5. | Replace the management module. |
| 6. | Replace the midplane. |
|
|
|
I/O module error messages
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician.
Message | Action |
|
|
Switch fault x | 1. Reseat I/O module x. |
| |
| 2. Replace I/O module x. |
|
|
Switch module x was removed | Information only. Take action as required. |
|
|
Switch module x was installed | Information only. Take action as required. |
|
|
Switch module x was powered on | Information only. Take action as required. |
|
|
Switch module x was powered on | Information only. Take action as required. |
|
|
Switch System running nonredundant | Information only. Take action as required. |
switch modules |
|
|
|
74BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide