Error message/symptom

FRU/action

 

 

 

 

240

(CPU board cache controller QuadT bus error)

1.

Memory board

 

 

 

 

2.

Processor board

 

 

3.

Midplane board

 

 

 

241

(CPU board cache controller error)

Processor board

 

 

 

 

245

(No configurable memory detected)

1.

Verify DIMM installation order.

 

 

 

 

2.

Reseat DIMMs, re-enable DIMMs, if necessary, using

 

 

 

the Configuration/Setup Utility program, and run

 

 

 

diagnostics.

 

 

3.

Replace failing DIMMs.

 

 

4.

Memory board.

 

 

 

247

(Error port n after WIAP SMI)

Memory board

 

 

 

248

(Memory board RIAP not complete on port n)

Memory board

 

 

 

249

(Memory board RIAP failed on port n)

Memory board

 

 

 

265

(Memory board SMI initialization error on port n)

Memory board

 

 

 

 

266

(Service processor machine check reported, disabled

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

DIMM x and DIMM y.)

 

using the Configuration/Setup Utility program, and

 

 

 

 

 

 

run diagnostics.

 

 

2.

Replace failing DIMMs.

 

 

3.

Memory board.

 

 

 

267

(Service processor machine check reported, disabled

Processor board

cache)

 

 

 

 

 

 

268

(Uncorrectable error isolated to DIMMs x and y.)

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

 

 

 

 

 

using the Configuration/Setup Utility program, and

 

 

 

run diagnostics.

 

 

2.

Replace failing DIMMs.

 

 

3.

Memory board.

 

 

 

 

289

(Memory error detected, DIMM x disabled.)

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

 

 

 

 

 

using the Configuration/Setup Utility program, and

 

 

 

run diagnostics.

 

 

2.

Replace DIMM x.

 

 

3.

Enable the DIMM using the Configuration/Setup Utility

 

 

 

program.

 

 

4.

Memory board.

 

 

 

 

291

(Protexion: error DIMM x and y)

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

 

 

 

 

 

using the Configuration/Setup Utility program, and

 

 

 

run diagnostics.

 

 

2.

Replace failing DIMM.

 

 

3.

Memory board.

 

 

 

 

292

(Protexion: error DIMM x)

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

 

 

 

 

 

using the Configuration/Setup Utility program, and

 

 

 

run diagnostics.

 

 

2.

Replace failing DIMM.

 

 

3.

Memory board.

 

 

1162 (I/O board: Serial: port configuration error.)

I/O board

 

 

 

1200 (Node 0/CPU slot x: CPUID y: Machine check

1.

Microprocessor x

exception.)

2.

Processor board

 

 

 

 

 

 

152IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

Page 162
Image 162
IBM 8688 manual Error message/symptom FRU/action 240, 241, 245, 247, 248, 249, 265, 266, 267, 268, 289, 291, 292