Code/explanation

FRU/action

 

 

 

9106-xxx-xxx-xxx(ISMP indicates untested I2C bus.)

1.

Run diagnostic test again.

 

 

2.

Correct other error conditions, including other

 

 

system-management tests and items logged in

 

 

Remote Supervisor Adapter system-error log, and

 

 

retry.

 

3.

Disconnect all server and option power cords, wait 30

 

 

seconds, reconnect, and retry.

 

4.

Update the xSeries 450 node with the latest firmware

 

 

level of diagnostics, ISMP, and ASM. Update RXE

 

 

with latest ISMP firmware, and retry.

 

5.

If a 9106 error occurs again, follow the FRU/action for

 

 

error 9105 with respective parameter set.

 

 

 

9107-xxx-000-000(System Management BIST indicates

1.

Run Restart ASM Test and re-run ASM BIST Test.

failed tests.)

2.

Disconnect all server and option power cords from

 

 

 

server, wait 30 seconds, reconnect, and retry.

 

3.

Remote Supervisor Adapter.

 

 

 

RXE port error codes

Code/explanation

FRU/action

 

 

 

9204-091-094-011

1.

RXE cable A

(RXE Expansion Port A failure.)

2.

RXE expansion board to which cable is connected (Side A or Side

 

 

 

B)

 

3.

I/O board

 

 

 

9204-091-094-012

1.

RXE cable B

(RXE Expansion Port B failure.)

2.

RXE expansion board to which cable is connected (Side A or Side

 

 

 

B)

 

3.

Processor board

 

4.

Midplane board

 

 

 

9204-091-094-015

1.

Side A card in RXE100

(RXE100 Side A to Side B failure.)

2.

Side B card in RXE100

 

 

 

 

9204-091-094-016

1.

Side B card in RXE100

(RXE100 Side B to Side A failure.)

2.

Side A card in RXE100

 

 

 

9216-091-094-nnn

Restart the server. This usually means that an RXE cable has

(Receive Error on any port.)

been attached after SAL/EFI has run.

 

 

 

9220-091-094-011

1.

RXE cable B

(Transmit error on Port A.)

2.

RXE expansion board to which cable is connected (Side A or Side

 

 

 

B)

 

3.

I/O board

 

 

 

9220-091-094-012

1.

RXE cable B

(Transmit error on Port B.)

2.

RXE expansion board to which cable is connected (Side A or Side

 

 

 

B)

 

3.

Processor board

 

4.

Midplane board

 

 

 

9220-091-094-015

1.

Side A card in RXE100

(RXE100 Side A to Side B failure.)

2.

Side B card in RXE100

 

 

 

 

Chapter 6. Symptom-to-FRU index 173

Page 183
Image 183
IBM 8688 manual RXE port error codes