Service Processor message

FRU/action

 

 

 

Memory Card Machine Check CYC_MCK2

1.

Run diagnostics.

 

 

2.

Memory board.

 

3.

Processor board.

 

4.

I/O board.

 

5.

PCI-X board.

 

6.

Midplane board.

 

 

 

Native I/O Card Machine Check

1.

Remove adapters in PCI-X slots 1 and 2, and run

 

 

 

diagnostics.

 

2.

I/O board.

 

3.

Memory board.

 

4.

Midplane board.

 

 

 

PCI Card Machine Check

1.

Remove PCI adapters, and run diagnostics.

 

 

2.

PCI-X board.

 

3.

Memory board.

 

4.

Midplane board.

 

 

 

PCI Power Good Fault

1.

Remove PCI adapters and run diagnostics.

 

 

2.

PCI-X board.

 

 

 

Power supply 1-2 current exceeded max spec

1.

Check both power supplies are installed and connected to

value

 

ac.

 

 

 

2.

Power supply 1-2.

 

3.

Power backplane.

 

 

 

Power Supply 1-2 Current Fault

1.

Check/replace power supply 1-2.

 

 

2.

Power backplane.

 

 

 

Power Supply 1-2 Overcurrent Fault

1.

Check/replace power supply 1-2.

 

 

2.

Power backplane.

 

 

 

Power Supply 1-2 12v Overvoltage Fault

1.

Check/replace power supply 1-2.

 

 

2.

Power backplane.

 

 

 

Power Supply 1-2 12v Undervoltage Fault

1.

Check/replace power supply 1-2.

 

 

2.

Power backplane.

 

 

 

Power Supply 1-2 5v Undervoltage Fault

1.

Check/replace power supply 1-2.

 

 

2.

Power backplane.

 

 

Power Supply 1-2 ac Power Removed, Early

Check ac power inputs.

Power Off Warning

 

 

 

 

Power Supply 1-2 dc Good Fault

Check/replace power supply 1-2.

 

 

Power Supply 1-2 Fan Fault

Check/replace power supply 1-2.

 

 

Power Supply 1-2 Removed

Check/replace power supply 1-2.

 

 

 

Power Supply 1-2 Temperature Fault

1.

Check for airflow obstructions.

 

 

2.

Check/replace power supply 1-2.

 

 

 

System shutoff due to CPU 1-4 over

1.

Check for airflow obstructions.

temperature

2.

Check fans.

 

 

3.

Microprocessor 1-4.

 

 

 

Chapter 6. Symptom-to-FRU index 157

Page 167
Image 167
IBM 8688 manual Remove adapters in PCI-X slots 1 and 2, and run, Diagnostics, Remove PCI adapters, and run diagnostics