Table 10. Memory test error codes

(continued)

 

 

 

 

 

Error code/symptom

 

FRU/action

 

 

 

 

9307-xxx-00-00

 

1.

Restart the server, and run the test again.

(Test Aborted: Choppiest Internal Error.)

2.

If the symptom still exists, reflash the diagnostic code.

 

 

 

 

 

 

9308-xxx-00-00

 

1.

Restart the server, and run the test again.

(Diagnostic Program Error. Test Aborted: No DIMMs

2.

If the symptom still exists, reflash the diagnostic code.

installed.)

 

 

 

 

 

 

 

 

9309-xxx-00-00

 

1.

Reload the system, and run the test again.

(Test Aborted: Fast Scrub Error.)

 

 

2.

If the symptom still exists, replace the memory board.

 

 

 

 

 

 

9310-xxx-nn-nn

 

1.

Restart the server, and run the test again.

(Test Failed: ECC errors.)

 

 

2.

If the symptom still exists, replace the DIMMs.

nn= the DIMM connector designation, 1-28.

 

 

 

 

 

 

LED error codes

Table 11. LED error codes

Error code/symptom

FRU/action

 

 

 

9001-180-xxx-xxx

1.

Light Path Diagnostics card

(Failed Front LED panel test.)

2.

Power/reset card assembly

 

 

3.

Midplane board

 

4.

I/O board

 

 

 

9002-180-xxx-xxx

1.

Memory board

(Failed Memory Board LED test.)

2.

Midplane board

 

 

 

9003-180-xxx-xxx

PCI-X board

(Failed Active PCI LED test.)

 

 

 

 

 

9004-180-xxx-xxx

1.

Light Path Diagnostics card

(Failed Diagnostics LED test.)

2.

Midplane board

 

 

 

 

9005-180-xxx-xxx

1.

Fan

(Failed Fan LED test.)

2.

I/O board

 

 

 

9006-180-xxx-xxx

Midplane board

(Failed Centerplane LED test.)

 

 

 

 

9007-180-xxx-xxx

I/O board

(Failed I/O board LED test.)

 

 

 

 

 

9008-180-xxx-xxx

1.

SCSI backplane cable

(Failed SCSI Backplane LED test.)

2.

SCSI backplane

 

 

3.

Midplane board

 

 

 

Table 12. LED error codes for the RXE100 port

 

 

 

 

Error code/symptom

FRU/action

 

 

 

9021-180-xxx-xxx

1.

RXE Operator panel cable

(Failed RXE Operator panel LED test)

2.

RXE Operator panel

 

 

3.

RXE backplane

 

 

 

9022-180-xxx-xxx

1.

RXE PCI-X backplane (Side A)

(Failed RXE PCIXBackplane Side A LED test)

2.

RXE backplane

 

 

 

 

Chapter 6. Symptom-to-FRU index 175

Page 185
Image 185
IBM 8688 manual LED error codes