IDE DVD-ROM drive test error codes

Error Code/Explanation

FRU/Action

 

 

 

1900h (Critical/Command Error.)

1.

Replace media.

 

 

2.

Check drive cables and connections.

 

3.

Connect drive to other IDE channel.

 

4.

Drive.

 

5.

I/O board.

 

 

 

1901h (DVD Seek Test failed.)

1.

Replace media.

 

 

2.

Check drive cables and connections.

 

3.

Connect drive to other IDE channel.

 

4.

Drive.

 

5.

I/O board.

 

 

 

1902h (DVD Read Test failed.)

1.

Replace media.

 

 

2.

Check drive cables and connections.

 

3.

Connect drive to other IDE channel.

 

4.

Drive.

 

5.

I/O board.

 

 

 

SCSI test error codes

Code/Explanation

FRU/Action

 

 

 

0500h (SCSI device not ready.)

1.

Confirm that drive is configured.

 

 

2.

Check drive cables and connections.

 

3.

Drive.

 

4.

I/O board or SCSI add-on controller.

 

 

 

0502h (SCSI device read error.)

1.

Confirm that drive is configured.

 

 

2.

Check drive cables and connections.

 

3.

Drive.

 

4.

I/O board or SCSI add-on controller.

 

 

 

0506h (SCSI disk self test failed.)

1.

Confirm that drive is configured.

 

 

2.

Check drive cables and connections.

 

3.

Drive.

 

4.

I/O board or SCSI add-on controller.

 

 

 

0507h (SCSI disk buffer error.)

1.

Confirm that drive is configured.

 

 

2.

Check drive cables and connections.

 

3.

Drive.

 

4.

I/O board or SCSI add-on controller.

 

 

 

0508h (SCSI disk random read error.)

1.

Confirm that drive is configured.

 

 

2.

Check drive cables and connections.

 

3.

Drive.

 

4.

System I/O Board or SCSI add-on controller.

 

 

 

164IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

Page 174
Image 174