Error
message/symptom
FRU/action
1810
(Slot
x:
Unknown
PCI
error)
1.
Reconfigure
PCI/PCI-X
adapters.
2.
PCI
adapter.
3.
PCI-X
board.
1820
(Node
0/PCI
slot
x:
Master
Data
Parity
Error.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1821
(Node
0/PCI
slot
x:
Detected
Parity
Error.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1822
(Node
0/PCI
slot
x:
Signaled
System
Error.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1823
(I-node
0/PCI
slot
x:
Received
Master
Abort.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1824
(Node
0/PCI
slot
x:
Received
Target
Abort.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1825
(Node
0/PCI
slot
x:
Signaled
Target
Abort.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1826
(Node
0/PCI
slot
x:
PCI
Host
Bridge
detected
an
error.)
1.
PCI/PCI-X
adapter
2.
PCI-X
board
1962
(Start
of
[OS]
failed.)
Verify
operating
system
installation/startup
media.
Service
processor
messages
An

example

of
a

typical

service
processor
message
is

as

follows:

-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Log
Entry
#:
2
Logging
Source:
ServProc
Log
Type:
E,
I,
or
W
Date:
06/17/2003
Time:
6:17:3
Recoverable
Error
handling
example
message
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
This
message

indicates

simply

that
the

machine

was

turned

on
at
the

recorded

time.

The

possible

service
processor
error
messages

are

listed

in
the
following

table.

Note:

Try

reseating

a

suspected

component

or

reconnecting

a

cable

before

replacing

the

component.

154
IBM
xSeries
450
Type
8688:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide