vWhen using memory mirroring, you must install two pairs of DIMMs at a time. The four DIMMs in each bank must be identical. The following table shows the pairs that are in each bank. See Table 8 on page 98 for the DIMM connector pair assignments.

Table 9. Memory mirroring DIMM installation sequence

Set

DIMM pairs

Set

DIMM pairs

 

 

 

 

1

1 and 2

5

9 and 10

 

 

 

 

2

3 and 4

6

11 and 12

 

 

 

 

3

5 and 6

7

13 and 14

 

 

 

 

4

7 and 8

 

 

 

 

 

 

vWhen you install or remove DIMMs, the server configuration information changes. When you restart the server, the system displays a message indicating that the memory configuration has changed.

Complete the following steps to install a DIMM in your server:

1.Read the safety information beginning on page 197 and “Installation guidelines” on page 77.

2.Turn off the server and peripheral devices, and disconnect the power cords and all external cables; then, open the server cover.

Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78.

3.Open the DIMM access door that covers the DIMM connector into which you will be installing the DIMM.

Chapter 4. Installing options 99

Page 109
Image 109
IBM 8688 manual Set Dimm pairs