v
When
using
memory
mirroring,
you
must
install
two
pairs
of
DIMMs
at
a
time.
The
four
DIMMs
in
each
bank
must
be
identical.
The
following
table
shows
the
pairs
that
are
in
each
bank.
See
Table
8
on
page
98
for
the
DIMM
connector
pair
assignments.
Table
9.
Memory
mirroring
DIMM
installation
sequence
Set
DIMM
pairs
Set
DIMM
pairs
1
1
and
2
5
9
and
10
2
3
and
4
6
11
and
12
3
5
and
6
7
13
and
14
4
7
and
8
v
When
you
install
or
remove
DIMMs,
the
server
configuration
information
changes.
When
you
restart
the
server,
the
system
displays
a
message
indicating
that
the
memory
configuration
has
changed.
Complete
the
following
steps
to
install
a
DIMM
in
your
server:
1.
Read
the
safety
information
beginning
on
page
197
and
“Installation
guidelines”
on
page
77.
2.
Turn
off
the
server
and
peripheral
devices,
and
disconnect
the
power
cords
and
all
external
cables;
then,
open
the
server
cover.
Attention:
When
you
handle
static-sensitive
devices,
take
precautions
to
avoid
damage
from
static
electricity.
For
details
about
handling
these
devices,
see
“Handling
static-sensitive
devices”
on
page
78.
3.
Open
the
DIMM
access
door
that
covers
the
DIMM
connector
into
which
you
will
be
installing
the
DIMM.
Chapter
4.
Installing
options
99