Service Processor message

FRU/action

 

 

 

12V H Bus Fault

1.

Disk drives

 

 

2.

Disk drive backplane

 

3.

I/O board

 

4.

Power backplane

 

5.

Power cables

 

6.

Midplane board

 

 

 

5V Fault

1.

Remove PCI adapters, and see if the problem remains.

 

 

2.

I/O board.

 

 

Cable: Control Panel Not Present

Cable to Light Path panel

 

 

Cable: SCSI I2C cable not detected

Cable to SCSI backplane

 

 

 

Cable: Service Processor Not Present

1.

Remote Supervisor Adapter

 

 

2.

I/O board

 

 

 

Center Card Power Fault

1.

Midplane VRM

 

 

2.

Midplane board

 

 

 

CPU 1-4 Over Temperature

1.

Check airflow blockage

 

 

2.

Check fans

 

3.

Microprocessor 1-4

 

 

 

Failure reading I2C device. Check devices on

1.

Restart the server

bus x.

2.

I/O board

 

 

 

 

Fan 1-4 Failure

1.

Check fan connection.

 

 

2.

Fan.

 

 

 

Fan 1-4 not detected

1.

Check fan connection.

 

 

2.

Fan.

 

 

 

Fan 1-4 Outside Recommended Speed

1.

Check fan connection.

 

 

2.

Fan.

 

 

 

Invalid Fan configuration

1.

Check fan connections.

 

 

2.

Fans.

 

 

Hard Drive 1-2 Fault

Run diagnostics.

 

 

 

Hard Drive 1-2 removal detected

1.

Hard disk drive

 

 

2.

Run diagnostics

 

 

 

Integrated Systems Management Processor

1.

Remove ac power for 20 seconds, reconnect and reboot,

encountered failures upon starting

 

and run diagnostics.

 

 

 

2.

I/O board.

 

 

Invalid CPU configuration

Ensure microprocessor 1 is properly installed.

 

 

 

CPU Card Machine Check TOR_MCK

1.

Run diagnostics.

 

 

2.

Microprocessors.

 

3.

Processor board.

 

4.

Memory board.

 

5.

I/O board.

 

6.

Midplane board.

 

 

 

156IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

Page 166
Image 166
IBM 8688 manual Disk drives, Remove PCI adapters, and see if the problem remains, Cable to Light Path panel, Midplane VRM