Advanced System Management error codes

Code/explanation

FRU/action

 

 

 

9100-xxx-xxx-xxx(SAL/EFI failed to communicate with

1.

Run ASM Restart Test to restart ASM.

ASM.)

2.

Rerun diagnostic test.

 

 

3.

Correct other error conditions, including other failed

 

 

system management tests and items logged in

 

 

Remote Supervisor adapter system-error log, and

 

 

retry.

 

4.

Disconnect all server and option power cords from

 

 

server, wait 30 seconds, reconnect, and retry.

 

5.

Remote Supervisor Adapter.

 

6.

I/O board.

 

 

 

9101-000-000-000(DMC Self Test failed to complete.)

1.

Disconnect all server and option power cords

 

 

 

from server, wait 30 seconds, reconnect, and

 

 

retry.

 

2.

Update the ISMP on the xSeries 450 node and RXE

 

 

with the latest firmware level.

 

3.

RXE backplane if test on RXE unit, I/O board if test

 

 

on xSeries 450 node.

 

 

 

9102-000-000-000(DMC Self Test failed update.)

1.

Disconnect all server and option power cords

 

 

 

from server, wait 30 seconds, reconnect, and

 

 

retry.

 

2.

Update the ISMP on the xSeries 450 node and RXE

 

 

with the latest firmware level.

 

3.

RXE backplane if test on RXE unit, I/O board if test

 

 

on xSeries 450 node.

 

 

 

9103-000-000-000(DMC Self Test failed ROM.)

1.

Disconnect all server and option power cords

 

 

 

from server, wait 30 seconds, reconnect, and

 

 

retry.

 

2.

Update the ISMP on the xSeries 450 node and RXE

 

 

with the latest firmware level.

 

3.

RXE backplane if test on RXE unit, I/O board if test

 

 

on xSeries 450 node.

 

 

 

9104-000-000-000(DMC Self Test failed RAM.)

1.

Disconnect all server and option power cords

 

 

 

from server, wait 30 seconds, reconnect, and

 

 

retry.

 

2.

Update the ISMP on the xSeries 450 node and RXE

 

 

with the latest firmware level.

 

3.

RXE backplane if test on RXE unit, I/O board if test

 

 

on xSeries 450 node.

 

 

 

9105-004-000-000(ISMP indicates I2C errors on bus A0.)

1.

I/O board

 

2.

Midplane board

 

 

 

9105-004-001-000(ISMP indicates I2C errors on bus A1.)

1.

VRMs and microprocessors installed in midplane

 

 

board

 

2.

Midplane board

 

 

 

9105-004-002-000(ISMP indicates I2C errors on bus A2.)

1.

Memory board

 

2.

Midplane board

 

 

 

170IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

Page 180
Image 180
IBM 8688 manual Advanced System Management error codes