Error message/symptom

FRU/action

 

 

 

187

(I/O Card Fault: VPD serial number not set.)

I/O board

 

 

 

188

(I/O Card Fault: Bad EEPROM CRC#2.)

I/O board

 

 

 

 

201

(Invalid memory configuration.)

1.

Verify DIMM installation order.

 

 

 

 

2.

Reseat DIMMs, re-enable DIMMs, if necessary, using

 

 

 

the Configuration/Setup Utility program, and run

 

 

 

diagnostics.

 

 

3.

Replace failing DIMM.

 

 

4.

Memory board.

 

 

 

 

210

(Invalid memory configuration)

1.

Verify DIMM installation order.

 

 

 

 

2.

Reseat DIMMs, re-enable DIMMs, if necessary, using

 

 

 

the Configuration/Setup Utility program, and run

 

 

 

diagnostics.

 

 

3.

Replace failing DIMM.

 

 

4.

Memory board.

 

 

211 (Memory board error)

Memory board

 

 

 

212

(Memory board port 2 SMI parity error)

Memory board

 

 

 

213

(Memory board port 1 SMI parity error)

Memory board

 

 

 

 

214

(Error on memory board port 1.)

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

 

 

 

 

 

using the Configuration/Setup Utility program, and

 

 

 

run diagnostics.

 

 

2.

Replace failing DIMM.

 

 

3.

Memory board.

 

 

 

 

215

(Error on memory board port 2.)

1.

Reseat DIMMs, re-enable DIMMs, if necessary,

 

 

 

 

 

using the Configuration/Setup Utility program, and

 

 

 

run diagnostics.

 

 

2.

Replace failing DIMM.

 

 

3.

Memory board.

 

 

 

216

(Memory board error.)

Memory board

 

 

 

220

(DIMM in slot n is not DDR and ECC)

Replace with DDR ECC DIMM.

 

 

 

221

(DIMM in slot n has an unsupported number of

Replace with correct DIMM.

rows.)

 

 

 

 

 

222

(DIMM in slot n is an unsupported size.)

Replace with correct DIMM.

 

 

 

223

(DIMMs in slots m and n are not a valid pair.)

Ensure DIMMs in slots m and n are identical.

 

 

 

224

(DIMM capacity exceeded in port n, maximum 5

Review and populate DIMMs according to installation

pairs total when using 2 GB DIMMs.)

rules.

 

 

 

229

(Processor board: External cache error, cache

Processor board

disabled.)

 

 

 

 

 

230

(CPU board cache controller error)

Processor board

 

 

 

233

(CPU board cache controller Register error)

Processor board

 

 

 

236

(CPU board cache controller request error handler)

Processor board

 

 

 

237

(CPU board cache controller pending queue error)

Processor board

 

 

 

238

(CPU board cache controller L4 error)

Processor board

 

 

 

239

(CPU board cache controller coherence directory)

Processor board

 

 

 

 

Chapter 6. Symptom-to-FRU index 151

Page 161
Image 161
IBM 8688 Error message/symptom FRU/action 187, 188, 201, Verify Dimm installation order, 210, 212, 213, 214, 215, 216, 220