ERserver
Page
 ERserver
Page
 Important safety information
Online support
Page
 Contents
 Installing options
Field replaceable units
 Appendix B. Related service information
Parts listing xSeries 450 Type
Appendix A. Getting help and technical assistance
Page
 General information
Related publications
Page
 Features and specifications
 Server controls and indicators
What your IBM xSeries 450 offers
 Front view
 Rear view
 General information
 Turning on the server
Server power features
Turning off the server
 General information
Page
 Using the Extensible Firmware Interface EFI Boot Manager
 Starting the Configuration/Setup Utility program
Using the Configuration/Setup Utility program
Configuration/Setup Utility menu choices
 System Management Settings
Advanced Setup
Memory Configuration
Devices and I/O Ports
 Passwords
 Using the LSI Logic Configuration Utility program
Select Device Properties
 Remote Supervisor Adapter features
Setting up the Remote Supervisor Adapter
Setup requirements
 Click Manual for Startup Type
 Cabling and configuring the Remote Supervisor Adapter
Cabling the Ethernet LAN port and serial port
 Ethernet activity LED
Ethernet link LED
 Configuring the adapter
 Subnet Mask
Network Interface
IP Address
Gateway
 Baud Rate
Dedicated to ASM
 Stop Bits
 Line Type
Authentication Protocol
Remote IP Address
 Select Save New Remote Control Password, and press Enter
 Using the ASM interconnect network
Planning and cabling the interconnect network
 Connecting the ASM Interconnect module to the xSeries
Forwarding alerts
 ASM interconnect network configuration examples
 ASM
 Remote system management administrator system Modem XSeries
 Configuring the Gigabit Ethernet controller
Page
 Diagnostics
General checkout
 001 is the Server Part of a CLUSTER?
 Diagnostic tools overview
Post error codes and messages
 System-error logs
Light Path Diagnostics feature
 LEDs on the top of the server
Diagnostics panel
Diagnostic display
LEDs on the system boards
 Starting the AMIDiag program
Diagnostic programs, error codes, and messages
Text messages
Starting the AMIDiag program from the server
 Updating the firmware
 AMIDiag menus
Using AMIDiag keys
Key Description
 Running AMIDiag tests
Running the AMIDiag program in Batch Mode
To run this test or test group Do the following
 Quitting tests
System diagnostic tests
Error-log viewer
Processor test
 PCI System Test
System Board Test
Multiprocessor Test
 Memory diagnostic tests
IDE device diagnostic tests
 IDE CD-ROM tests
IDE DVD tests
 Scsi diagnostic tests
Atapi removables test
 Scsi Disk Buffer Test
Scsi Disk Self Diagnostic Test
Select Scsi Disk Self Diagnostic Test, and press Enter
Scsi Disk Read Test
 Scsi Disk Spin Down Test
Scsi Disk Write Test
Scsi Disk Format Test
Scsi Disk Quick Test
 Scsi CD-ROM tests
 Scsi Tape Buffer Test
Scsi Tape Test
Scsi Tape Read Test
 Scsi Tape Write Test
Video diagnostic tests
Scsi Tape Rewind Test
Parameter
 Test Name Test Description Type of Monitor
Running video tests
Video Monitor Test
Subtest Description
 USB Functionality Test
USB diagnostic tests
Video Controller Test
USB Keyboard Test
 Parameter Action
Keystroke Scan Code Ascii Code
 Shift Alt
 Upper case shift keyboard scan/ASCII codes
 Ctrl keyboard ASCII/scan codes
 Ctrl+d EOT Ctrl+f ACK Ctrl+g BEL
 Alt keyboard scan/ASCII codes
 USB Mouse Test
Miscellaneous diagnostic tests
Serial port test
 LED Test
RXE Port Test
 Advanced System Management Test
 Options menu
Edit Batch Parameters
 Break All on Error
Cycle Mode
Test Mode
Cycle Number
 Break Test on Error
Cycle Test Mode
Wait on Error
Cycle TLimit Hrs
 Quick Test use Description
 Diagnostics
 Load Batch Parameters
 Save Batch Parameters
Generate Report
 Toggle All Tests in Menu
Ethernet diagnostic tests
Diagnostic error code tables
Run Selected Tests
 Recovering SAL/EFI code
Small computer system interface Scsi messages
 Clearing a power-on password
 Clearing Cmos
 Power checkout
 Troubleshooting the Ethernet controller
Network connection problems
 Ethernet controller problems FRU/actions
Ethernet controller troubleshooting chart
Ethernet controller messages
 Working inside a server with power on
Installation guidelines
System reliability considerations
 Handling static-sensitive devices
Major components of the xSeries 450 server
 Dimm
 Connector and LED locations
Memory board internal connectors and LEDs
 Memory switch card LEDs
 Front side
Processor board internal connectors and LEDs
Reverse Side
 Following illustrations show the LEDs on the processor board
 Midplane board connectors and LEDs
Following illustration shows the LEDs on the midplane board
 LED number Board
 PCI-X board internal connectors and LEDs
 Board internal connectors
Board jumpers
 Remote Supervisor Adapter connectors and LEDs
Opening the cover
 Removing and replacing the bezel
 Removing and replacing a hot-swap power supply
 AC LED
 Installing an adapter
Bus Slot Supported adapter speed MHz
 Installing options
 PCI-X
 Installing a hot-swap hard disk drive
 Installing a 1.44 MB diskette drive
Removable media bays Filler panel
 Installing a CD-ROM or DVD-ROM drive
 Installing memory
Pair Dimm connectors Port
 Set Dimm pairs
 Installing and replacing a microprocessor and power module
 Microprocessor 2 socket Installing options
Page
 Shipping thumbscrews
Page
 Unlocked Locked
Page
 Replacing and troubleshooting fans
Replacing fan 1 or
 Replacing fan 3 or
 Replacing the battery
 Do not
 Connecting the cables
Completing the installation
Closing the cover
 Updating your server configuration
 Installing the server in a rack
Page
 Memory board
Memory-board assembly
Before you begin
 Memory-board voltage regulator module VRM
 Close the Dimm access door
 Memory switch card and cable
 Processor-board assembly
 Levers
 Microprocessor and power module
 Processor-board VRM
 PCI-X board assembly
Page
 Midplane board
 Midplane-board VRM
 PCI-X board
 Remove any cables that are attached to the PCI-X board
 Active PCI assembly
 Board, riser card, and Remote Supervisor Adapter
 Completed Success
 PCI-X
 Field replaceable units
 Select Network Interfaces/Protocols, and press Enter
Restoring the nonvolatile EFI variables
Click Network Interface
 Select Boot Options Maintenance Menu, and press Enter
Page
 Top cover assembly
 Top power board
Hard disk drive backplane
 Media bay card
 Memory-board retaining latches
 AC box assembly mechanism
 Replace FAN Front For Proper
 Media-extract mechanism
 Power/reset card assembly
Light Path card
 Field replaceable units
Page
 See the system-error log
Light Path LED errors
System-error log is 75% full clear the log
Before replacing any FRU
 Turn off the server and disconnect the ac power cord
Check Dimm error LED on memory board
PCI-X BUS LED on adapter Check the system-error log
Event Log See the system-error log PS1 LED on Power supply
 Ensure that ac power is applied to both power supplies
System-error log entries
Error
Information
 SAL/EFI messages
 Reseat DIMMs, re-enable DIMMs, if necessary
Error message/symptom FRU/action 187
Verify Dimm installation order
Using the Configuration/Setup Utility program,
 245
Error message/symptom FRU/action 240
241
247
 Reconfigure PCI/PCI-X adapters
Error message/symptom FRU/action 1205
Update service processor firmware
1331
 Service processor messages
 Microprocessor 2 power module
Service Processor message FRU/action
Microprocessor 3 power module
Microprocessor 4 power module
 Ensure microprocessor 1 is properly installed
Remove PCI adapters, and see if the problem remains
Remove ac power for 20 seconds, reconnect and reboot
Disk drives
 Remove PCI adapters and run diagnostics
Diagnostics
Remove PCI adapters, and run diagnostics
Check both power supplies are installed and connected to
 Configuration/Setup Utility program, and run diagnostics
Check room temperature
Reseat DIMMs, re-enable DIMMs, if necessary, using
Check microprocessor 1-4 power module cable
 Diagnostic error codes
System-error codes
 Run Configuration/Setup Utility program
Error Code/Symptom FRU/action
Run the Configuration/Setup Utility program
Reseat all PCI devices
 Manually eject media
IDE CD test error codes
Error Code/Explanation FRU/Action
Manually close drive
 Atapi removables test error codes
Check drive cables and connections
 0F03h Read failed
 Confirm that drive is configured
IDE DVD-ROM drive test error codes
Scsi test error codes
Code/Explanation FRU/Action
 Check if a tape is in drive
Confirm that drive is formatted and configured
Check if write test has been run
 Manually eject media and close drive
Check if a CD is in drive
Check if AMIDiag CD is present in drive
 Video test error codes
USB test error codes
 Check USB hub connection
Check USB mouse connection
Check USB keyboard connection
1302h
 Serial port test error codes
 Advanced System Management error codes
 Light Path card
PCI devices on PCI-X card
Hard disk drive backplane
Memory DIMMs
 See the Hardware Maintenance Manual for the RXE-100
 RXE port error codes
 Memory test error codes
Xxx-00-00 Restart the server, and run the test again
 LED error codes
 Error symptoms
 Startup boot microprocessor is not working properly
Device drivers are installed correctly
Memory problems Make sure that
Reseat microprocessors and power modules
 Language
Symptom Suggested action
Option problems Make sure that
Reseat boards, VRMs, and microprocessors
 Reseat microprocessor
Universal Serial Bus USB Verify that Port problems
Reseat boards and VRMs
System
 Front Power good Good Power on Indicators
Power supply LED errors
Light Midplane Description FRU/action
 Hardware status error codes
Diagnostic display error codes
Display report Device
 Phase 3 subsystem control status error codes
 SAL/EFI progress codes
Error message/explanation FRU/action
Microprocessors
 Scsi error messages
Power-on the server
 Ethernet error messages
Undetermined problems
Page
 Parts listing xSeries 450 Type
System
 Index XSeries 450 Models 4RX, 5RX, 6RX FRU No
CRU/FRU
 Miscellaneous parts kit 4RX, 5RX, 6 RX
 Figure a
 Figure B
 Keyboard CRUs
Keyboard FRU No
 Power cord CRUs
Power cord FRU No
Page
 Appendix A. Getting help and technical assistance
Before you call
 Software service and support Hardware service and support
 Safety information
General safety
 Electrical safety
 Safety inspection guide
 Grounding requirements
 Safety notices multilingual translations
 To Connect To Disconnect
 Do not
 ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb ≥ 55 kg 121.2 lb
 Importante
 Instrução
Para Conectar Para Desconectar
 Cuidado
 Cuidado
Instrução
 Cuidado
Page
 Appendix B. Related service information
Page
 Appendix B. Related service information
Page
 Appendix B. Related service information
 Connexion Déconnexion
 Faites-vous aider pour soulever ce produit
Page
 Hinweis
Wichtig
Kabel anschlieβen Kabel lösen
 Achtung
 ≥18 kg ≥32 kg
 Hinweis
Achtung
 Avviso
Per collegare Per scollegare
 Attenzione
 ≥18 kg ≥32 kg
 Avviso
Attenzione
 Appendix B. Related service information
Page
 50 Kg Appendix B. Related service information
Page
 Appendix B. Related service information
 110
 Declaración
Para la conexin Para la desconexiín
 Precaución
 Declaración
Precaución
 Precaución
 Appendix C. Notices
Edition notice
 Trademarks
Important notes
 Product recycling and disposal Battery return program
 European Union EMC Directive conformance statement
Industry Canada Class a emission compliance statement
Avis de conformité à la réglementation d’Industrie Canada
 Appendix C. Notices
 Macedonia former Yugoslav Republic of, Madagascar, Mali
 Appendix C. Notices
Page
 Index
 See also k test read test
 SAL/EFI
 See Post
 Test
Page
Page
 Part Number 48P9738