Code/Explanation
FRU/Action
0550h
(Read
timeout
.)
1.
Confirm
that
drive
is
configured.
2.
Check
drive
cables
and
connections.
3.
Drive.
4.
I/O
board
or
SCSI
add-on
controller.
0560h
(File
not
found.)
1.
Check
if
AMIDiag
CD
is
present
in
drive.
2.
Confirm
that
drive
is
configured.
3.
Check
drive
cables
and
connections.
4.
Drive.
5.
I/O
board
or
SCSI
add-on
controller.
0580h
(Cannot
allocate
memory.)
Restart
the
server
and
retry.
0590h
(Command
not
supported.
Unable
to
run
the
test
on
the
device.)
1.
Confirm
that
drive
is
configured.
2.
Check
drive
cables
and
connections.
3.
Drive.
4.
I/O
board
or
SCSI
add-on
controller.
Video
test
error
codes
Code/Explanation
FRU/Action
0900h
(Vertical
Synchronization
Test
failed.)
I/O
board
0901h
(Horizontal
Synchronization
Test
failed.)
I/O
board
0902h
(Graphics
controller
test
failed.)
I/O
board
0903h
(Attribute
controller
test
failed.)
I/O
board
0904h
(DAC
register
test
failed.)
I/O
board
0905h
(Video
adapter
memory
R/W
test
failed
.)
I/O
board
2100h
(Video
adapter
attribute
test
failed.
)
1.
Video
monitor
2.
I/O
board
2102h
(Video
adapter
color
test
failed.)
1.
Video
monitor
2.
I/O
board
2110h
-
2120h
(Param1
x
Param2
mode
test
failed.)
1.
Video
monitor
2.
I/O
board
USB
test
error
codes

If

any

of
the
following
USB

errors

occur

on

devices

not

directly

attached

to
a
USB
port
on
the
xSeries

450

(for

example,

a
USB

mouse

attached

to
a
USB

keyboard

with
an
internal
USB

hub),

connect

the

suspect

device

directly

to
the
xSeries

450

and

re-run

the

failing

test
to

isolate

whether

the

failure

is
with
an

intermediate

device,

the
device

being

tested,

or
the
USB

subsystem

of
the
xSeries

450.

In

cases

where

the

direct

attachment

passes,

replace

the

intermediate

devices

and

re-test

in
the

original

configuration

before

replacing

the
device

being

tested

or
the

I/O

board.
Chapter
6.
Symptom-to-FRU
index
167