Code/explanation

FRU/action

 

 

9220-091-094-016

1. Side B card in RXE100

(RXE100 Side B to Side A failure.)

2. Side A card in RXE100

 

 

 

9228-091-094-011

Missing cable on Port A

(No incoming power on Port A.)

 

 

 

9228-091-094-012

Missing cable on Port B

(No incoming power on Port B.)

 

 

 

9228-091-094-014

Missing cable on RXE100 Side A Port A

(No incoming power on port.)

 

 

 

9228-091-094-017

Missing cable on RXE100 Side B Port B

(No incoming power on port.)

 

 

 

9232-091-094-011

Missing cable on Port A

(Driver disabled on Port A.)

 

 

 

9232-091-094-012

Missing cable on Port B

(Driver disabled on Port B.)

 

 

 

9232-091-094-014

Missing cable on RXE100 Side A Port A

(Driver disabled on port.)

 

 

 

9232-091-094-017

Missing cable on RXE100 Side B Port B

(Driver disabled on port.)

 

 

 

9236-091-094-011

Missing cable on Port A

(Port A is disabled.)

 

 

 

9236-091-094-012

Missing cable on Port B

(Port B is disabled.)

 

 

 

9236-091-094-014

Missing cable on RXE100 Side A Port A

(RXE100 Side A Port A is disabled.)

 

 

 

9236-091-094-017

Missing cable on RXE100 Side B Port B

(RXE100 Side B Port B is disabled.)

 

 

 

Memory test error codes

Table 10. Memory test error codes

Error code/symptom

FRU/action

 

 

 

9301-xxx-00-00

1.

Restart the server, and run the test again.

(Test Aborted: Memory Hole Size Error.)

2.

If the symptom still exists, then update the SAL/EFI.

 

 

 

 

9302-xxx-00-00

1.

Restart the server, and run the test again.

(Test Aborted: DIMM Configuration Error.)

2.

If the symptom still exists, then update the SAL/EFI.

 

 

 

 

9303-xxx-00-00

1.

Restart the server, and run the test again.

(EFI operating system error. Test Aborted: Buffer too

2.

If the symptom still exists, reload the EFI operating

small.)

 

system.

 

 

 

 

 

9304-xxx-00-00

1.

Restart the server, and run the test again.

(EFI operating system error. Test Aborted: Invalid

2.

If the symptom still exists, reload the EFI operating

Parameter.)

 

system.

 

 

 

 

 

9305-xxx-00-00

1.

Restart the server, and run the test again.

(Test Aborted: Memory WRT not complete.)

2.

If the symptom still exists, replace the memory board.

 

 

 

 

9306-xxx-00-00

1.

Restart the server, and run the test again.

(Memory Diagnostic Program Error. Test Aborted: Invalid

2.

If the symptom still exists, reflash the diagnostic code.

Bank Selected.)

 

 

 

 

 

174IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

Page 184
Image 184
IBM 8688 manual Memory test error codes, Xxx-00-00 Restart the server, and run the test again