Code/explanation
FRU/action
9220-091-094-016
(RXE100
Side
B
to
Side
A
failure.)
1.
Side
B
card
in
RXE100
2.
Side
A
card
in
RXE100
9228-091-094-011
(No
incoming
power
on
Port
A.)
Missing
cable
on
Port
A
9228-091-094-012
(No
incoming
power
on
Port
B.)
Missing
cable
on
Port
B
9228-091-094-014
(No
incoming
power
on
port.)
Missing
cable
on
RXE100
Side
A
Port
A
9228-091-094-017
(No
incoming
power
on
port.)
Missing
cable
on
RXE100
Side
B
Port
B
9232-091-094-011
(Driver
disabled
on
Port
A.)
Missing
cable
on
Port
A
9232-091-094-012
(Driver
disabled
on
Port
B.)
Missing
cable
on
Port
B
9232-091-094-014
(Driver
disabled
on
port.)
Missing
cable
on
RXE100
Side
A
Port
A
9232-091-094-017
(Driver
disabled
on
port.)
Missing
cable
on
RXE100
Side
B
Port
B
9236-091-094-011
(Port
A
is
disabled.)
Missing
cable
on
Port
A
9236-091-094-012
(Port
B
is
disabled.)
Missing
cable
on
Port
B
9236-091-094-014
(RXE100
Side
A
Port
A
is
disabled.)
Missing
cable
on
RXE100
Side
A
Port
A
9236-091-094-017
(RXE100
Side
B
Port
B
is
disabled.)
Missing
cable
on
RXE100
Side
B
Port
B
Memory
test
error
codes
Table
10.
Memory
test
error
codes
Error
code/symptom
FRU/action
9301-xxx-00-00
(Test
Aborted:
Memory
Hole
Size
Error.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
then
update
the
SAL/EFI.
9302-xxx-00-00
(Test
Aborted:
DIMM
Configuration
Error.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
then
update
the
SAL/EFI.
9303-xxx-00-00
(EFI
operating
system
error.
Test
Aborted:
Buffer
too
small.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
reload
the
EFI
operating
system.
9304-xxx-00-00
(EFI
operating
system
error.
Test
Aborted:
Invalid
Parameter.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
reload
the
EFI
operating
system.
9305-xxx-00-00
(Test
Aborted:
Memory
WRT
not
complete.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
replace
the
memory
board.
9306-xxx-00-00
(Memory
Diagnostic
Program
Error.
Test
Aborted:
Invalid
Bank
Selected.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
reflash
the
diagnostic
code.
174
IBM
xSeries
450
Type
8688:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide