| t r o u b l e s h o o t i n g | |
|
|
|
|
| |||
CombiTouch MOTOR CONTROL ERROR CODES |
| ||
|
|
|
|
|
|
|
|
Type of Error | Indication | Release of Error |
|
|
|
|
|
Undervoltage | LED fl ashing sequence, with 1 fl ash per period. | Voltage of intermediate circuit is less than 250V |
|
|
|
|
|
Overvoltage | LED fl ashing sequence, with 2 fl ashes per period. | Voltage of intermediate circuit exceeds 445V |
|
|
|
|
|
Excess | LED fl ashing sequence, with 3 fl ashes per period. | Temperature sensor in the power unit is more than 93°C |
|
Temperature |
| ||
|
|
| |
|
|
|
|
Overcurrent | LED fl ashing sequence, with 4 fl ashes per period. | Blocked motor, detected by current peak monitoring from |
|
900 rpm rotating fi eld |
| ||
|
|
| |
|
|
|
|
Overcurrent | LED fl ashing sequence, with 5 fl ashes per period. | Intermediate circuit current exceeds 4.0A |
|
|
|
|
|
LED fl ashing sequence, with 6 fl ashes per period. | Release of interrupt at intermediate circuit current larger |
| |
than 53A |
| ||
|
|
| |
|
|
|
|
Power on | LED fl ashing sequence, with 7 fl ashes per period. | Effective mains voltage does not correspond to jumper |
|
setting 115V/230V |
| ||
|
|
| |
|
|
|
|
Watchdog | LED fl ashing sequence, with 8 fl ashes per period. | Watchdog of the microcontroller released, program crash |
|
|
|
|
|
47