Tr o u b l e s h o o t i n g
emergency operation mode (continued)
ERROR CODES
When the oven malfunctions, an error code will appear in the display.
PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.
The icons that begin to flash represent operational modes that are still usable.
When the oven fault is corrected, the Combitherm will return to normal operation.
Error |
| Model |
| Mode |
| |||
Display Shows |
|
|
|
|
|
| ||
ES | ESG | Steam | Combination | Convection | Retherm | |||
Code | ||||||||
|
| ESI |
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
E01 | Low Water Boiler | Yes | No | No | No | To 365°F | No | |
|
|
|
|
|
|
|
| |
E02 | Control Temp High | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
| |
E03 | Fan Motor Error | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
| |
E04 | Fan Motor 2 Error | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
| |
E11 | Convection Temperature High | Yes | Yes | BOILER UNITS | No | No | No | |
|
|
|
| ONLY |
|
|
| |
|
|
|
|
|
|
|
| |
E13 | Boiler Temperature High | Yes | No | No | No | Yes | No | |
|
|
|
|
|
|
|
| |
E15 | Condenser Temperature High | Yes | Yes | No | No | To 356°F | No | |
|
|
|
|
|
|
|
| |
E20 | B11 Core Temperature Probe Single Point | Yes | Yes | No | No | No | No | |
| Fault - HACCP only |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
E21 | N6 Cavity Probe Fault | Yes | Yes | BOILER UNITS | No | No | No | |
|
|
|
| ONLY |
|
|
| |
|
|
|
|
|
|
|
| |
E22 | B10 Core Temp Probe Fault | Yes | Yes | BY TIME ONLY | BY TIME ONLY | BY TIME ONLY | BY TIME ONLY | |
|
|
|
|
|
|
|
| |
E23 | B4 Boiler Probe Fault | Yes | No | No | No | No | No | |
|
|
|
|
|
|
|
| |
E24 | B5 Bypass Probe Fault | Yes | Yes | No | No | Yes | No | |
|
|
|
|
|
|
|
| |
E25 | B3 Condenser Probe Fault | Yes | Yes | Yes | No | To 356°F | No | |
|
|
|
|
|
|
|
| |
E26 | N8 Boiler Safety Temperature Probe Fault | Yes | No | No | No | No | No | |
|
|
|
|
|
|
|
| |
E27 | Boiler Element Temperature High | Yes | No | No | No | Yes | No | |
|
|
|
|
|
|
|
| |
E34 | Steam Generator Drain Pump Fault | Yes | No | No | No | No | No | |
|
|
|
|
|
|
|
| |
E36 | Steam Temperature High | Yes | No | No | No | Yes | No | |
|
|
|
|
|
|
|
| |
E51 | No Water in Boiler | Yes | No | No | No | Yes | No | |
|
|
|
|
|
|
|
| |
E53 | Fan Motor High Temperature | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
| |
E54 | Fan Motor 2 High Temperature | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
| |
E55 | Vent Not Open | Yes | Yes | Yes | Yes | Yes | Yes | |
|
|
|
| (NO BROWNING) | (NO BROWNING) | (NO BROWNING) | (NO BROWNING) | |
|
|
|
|
|
|
|
| |
E57 | No Rinse Water | Yes | Yes | Yes | Yes | Yes | Yes | |
|
|
|
|
|
|
|
| |
E93 | Communication Error FROM Display Board | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
| |
E94 | Communication Error TO Display Board | Yes | Yes | No | No | No | No | |
|
|
|
|
|
|
|
|
42