M2488 PRODUCT GUIDE

MTU DIAGNOSTIC SPECIFICATIONS

The tests can be set using the following parameters:

DIAG parameter 1:

For “FRD READ”, “BWD READ” or “WRITE”, set the operation mode.

0x00

-

STREAMING

: Set a continuous read (or write) operation.

0x01

-

START/STOP

:

Set the start/stop operation.

 

: For “LOCATE”, specify a sector. Specify a location sector from 1 to 99.

DIAG parameter 2: For “FWD READ”, “BWD READ”, “WRITE”, “FRD/BRD”, “L.W.R.” and “FEED

 

 

THR”, specify a test wrap.

0x00

- WRAP 1

:

Wrap-1 test

0x01

- WRAP 2

:

Wrap-2 test

DIAG parameter 4: For “WRITE”, select a write data pattern from the following:

0x00

-

D.S.E. PT

:

D.S.E. pattern

0x01

-

2 F PT

:

2F pattern

0x02

-

1/6 F PT

:

1/6F pattern

0x03

-

1/5 F PT

:

1/5F pattern

0x04

-

1/4 F PT

:

1/4F pattern

0x05

-

1/3 F PT

:

1/3F pattern

0x06

-

1/2 F PT

:

1/2F pattern

0x07

-

1 F PT

:

1F pattern

0x08

-

1/12 F PT

:

1/12F pattern

0x09

-

1.5 F PT

:

1.5F pattern

DIAG parameter 5:

For “L.W.R.”, select a path of the Loop Write To Read command from the following:

0x00

-

PATH:A

:

Path A

0x01

-

PATH:B

:

Path B

DIAG parameter 6:

For “L.W.R.”, set a level of the Loop Write To Read command from the following:

0x00

-

LEVEL LO

:

Low level

0x01

-

LEVEL HI

:

High level

execution time: When diag parameter 1 is START/STOP, set the GO ON time (time when the tape is running).1 count is 10msec.

If this parameter is set to “0,” the GO ON time becomes 10 ms.

: For the path test, specifies start position by the machine reel counter.

stop time: When diag parameter 1 is START/STOP, set the GO OFF time (time when the tape is not running). 1 count is 10msec.

If this parameter is set to “0,” the GO OFF time becomes 0 ms.

: For the path test, specifies end position by the machine reel counter.

execute count: Specify an execution count. Specify a command execution count from 1 to 99,999. When 0 is set, the command execution continues with no stop.

H-4.3.2 LOAD/UNLOAD: Two diagnostic tests to check loading and unloading

(Set the tests in detail using the given parameters.)

1)

NO CTG:

Loader and Threader test not using cartridge-------

CMD CD : 0x20

2)

WITH CTG:

Loader and Threader test using cartridge.-------

CMD CD : 0x21

The tests can be set using the following parameters:

DIAG parameter 2:

For NO CTG, select a test type from the following:

0x00 -

LOADER

: Loader test

0x01 -

THREADER

: Threader test.

DIAG parameter 3:

For WITH CTG, select a loading position from the following:

April 1997

CG00000-011503 REV. A

H-5

Page 487
Image 487
Fujitsu M2488 manual Streaming, Start/Stop, E. Pt, Patha, Pathb, Level LO, Level HI, Loader